Product Overview

Charger
RFID card
swiping area
Strip light
Type 2 socket
4
PV power preferred*
PV power adaptive charging with a high PV
self-consumption rate.
Automatic phase switchover to maximize PV
power utilization (available on AP22N-EU).
Scheduled charging
Scheduled time-of-use charging allows you to set
when to start and stop a charging session on the
app.
Normal charging
Charging power up to 7.4 kW (single-phase) or
22 kW (three-phase).
Smart authentication
Supports user authentication and denies access
for unauthorized users. Plug-and-play charging is
supported after authentication is disabled.
Supports RFID card management.
Power equalization*
The charger power is dynamically controlled
based on the total premise power to prevent the
premise RCBO from tripping.
* This function is available when an electricity
meter and a Huawei PV inverter of specified
models and versions are installed. Scan the QR
code in "About This Manual" and see detailed
information about the meter in "Meter
Description."
Technical Specifications
180 mm
AP07N-EU
Dimensions (H x W x D)
335 mm x 180 mm x 145 mm
Weight
About 3.0 kg
Operating voltage range
Single-phase 230 V AC (±20%)
Supported earthing system
Single-phase, three-wire; TN, TT, IT
Frequency
50/60 Hz±1 Hz
Rated output power
Single-phase: 7.4 kW (32 A)
(current)
WiFi 2.4 GHz
Network type
Bluetooth
BLE 5.0
Ethernet port
FE 100 Mbit/s
RFID
IEC 14443 Type A
Operating temperature*
–35°C to +45°C
Transportation and
–40°C to +70°C
storage temperature
5%–95% RH (non-condensing)
Relative humidity
0–2000 m
Altitude*
IP54
IP rating
EN 61851-1 2019, IEC 62955 2018
Standard compliance
IEC 61008-1 2010, IEC/EN 62196-1
*AP07N-EU: When the operating temperature ranges from 45°C to 55°C, the output power of the charger is derated.
When the altitude ranges from 2000 m to 4000 m, the output power of the charger is derated.
*AP22N-EU: When the operating temperature ranges from 40°C to 55°C, the output power of the charger is derated.
When the altitude ranges from 2000 m to 4000 m, the output power of the charger is derated.
145 mm
335 mm
AP22N-EU
335 mm x 180 mm x 145 mm
About 3.1 kg
Three-phase 400 V AC (±20%)
Three-phase five-wire; TN, TT
50/60 Hz±1 Hz
Three-phase: 22 kW (32 A)
WiFi 2.4 GHz
BLE 5.0
FE 100 Mbit/s
IEC 14443 Type A
–35°C to +40°C
–40°C to +70°C
5%–95% RH (non-condensing)
0–2000 m
IP54
EN 61851-1 2019, IEC 62955 2018
IEC 61008-1 2010, IEC/EN 62196-1