To open the fresh water tank spigot, turn the lever on
the spigot.
Figure 23
1. Fresh water tank
2. Filler cap

Filling the Spray Tank

Important: Ensure that the chemicals you will
be using are compatible for use with Viton (see
the manufacturer's label; it should indicate if it
is not compatible). Using a chemical that is not
compatible with Viton will degrade the O-rings in
the sprayer, causing leaks.
Important: Verify that the proper application rate
has been set prior to filling the tank with chemicals.
1. Stop the sprayer on a level surface, move the range
selector to the Neutral position, stop the engine,
and set the parking brake.
2. Ensure that the tank drain valve is closed.
3. Determine the amount of water needed to mix the
amount of chemical you need as prescribed by the
chemical manufacturer.
4. Open the tank cover on the spray tank.
The tank cover is located in the center of the top of
the tank (Figure 24). To open it, turn the front half
of the cover counterclockwise and swing it open.
You can remove the strainer inside for cleaning. To
seal the tank, close the cover and rotate the front
half clockwise.
3. Spigot
1
1. Tank cover
5. Add 3/4 of the required water to the spray tank
using the anti-siphon fill receptacle.
Important: Always use fresh clean water in
the spray tank. Do not pour concentrate into
an empty tank.
6. Start the engine, press the accelerator pedal to the
floor, and set the neutral engine speed lock to the
On position.
7. Set the pump switch to the On position.
8. Set the master boom switch to the Off position.
The Spray Pro monitor will display "HOLD".
9. Turn the agitation control valve to the 9 o'clock
position to start agitation in the tank.
10. Add the proper amount of chemical concentrate to
the tank, as directed by the chemical manufacturer.
Important: If you are using a wettable powder,
mix the powder with a small amount of water to
form a slurry before adding it to the tank
11. Add the remaining water to the tank.

Operating the Booms

Note: For the following section to apply, you must
obtain and install a boom kit and nozzles. Contact
your Authorized Toro Distributor for information on
the available boom kits and accessories. After you
install your booms and nozzles and before using the
sprayer for the first time, adjust the boom bypass valves
so that the pressure and application rate remains the
same for all booms when you turn one or more booms
off. Refer to Adjusting the Boom Bypass Valves.