range of the nozzles or there is a problem with the
spray system.

Cleaning the Sprayer

Important: You must always empty and clean the
sprayer immediately after each use. Failure to do
so may cause the chemicals to dry or thicken in the
lines, clogging the pump and other components.
Clean the spray system after each spraying session. To
properly clean the spray system:
• Use three separate rinses.
• Use a minimum of 50 gallons for each rinse.
• Use the cleaners and neutralizers as recommended
by the chemical manufacturers.
• Use pure clean water (no cleaners or neutralizers)
for the last rinse.
The rinse tank is located at the front, right side of the
chemical tank (Figure 25). If you install the optional
Rinse Kit, you can fill this tank with fresh water and
automatically rinse the main tank, boom supply lines
and nozzles.
Figure 25
1. Rinse tank (for use with the optional rinse kit, 106-4842)
1. Stop the sprayer, set the parking brake, place the
range selector in the Neutral position, and turn off
the engine. The tank will drain to left side of the
machine.
2. Locate the tank drain valve on the right side of the
machine (Figure 26). The valve is on the fender
bracket next to the battery.
2
1. Tank drain handle
A. Remove the lynch pin on the bracket securing
the drain valve to the machine and let the valve
rest on the ground.
B. Open the valve to drain any unused material
from the tank and dispose of it according to
local codes and the material manufacturer's
instructions (Figure 27). This allows any residual
material in the line to drain.
30
1
Figure 26
2. Lynch pin
g0131