Acceleration/deceleration reference current/lift mode starting frequency (Pr. 61 to Pr. 64)

Pr. 61 "reference current"
Pr. 62 "reference current for acceleration"
Pr. 63 "reference current for deceleration"
Pr. 64 "starting frequency for elevator mode"
Set these parameters to improve performance in the intelligent mode.
z
Parameter
Factory Setting
Number
61
62
63
64
<Setting>
( 1 ) Pr. 61 "reference current setting"
Setting
9999 (factory setting)
0 to 500A
( 2 ) Pr. 62 "reference current for acceleration"
(The reference value differs between the shortest acceleration/deceleration mode and optimum
acceleration/deceleration mode.)
The reference current setting can be changed.
Setting
9999 (factory setting)
0 to 200%
( 3 ) Pr. 63 "reference current for deceleration"
(The reference value differs between the shortest acceleration/deceleration mode and optimum
acceleration/deceleration mode.)
The reference current setting can be changed.
Setting
9999 (factory setting)
0 to 200%
( 4 ) Pr. 64 "starting frequency for elevator mode"
Setting
9999 (factory setting)
0 to 10Hz
Note: Pr. 61 to Pr. 64 are only valid when any of "1 to 6" is selected for Pr. 60.
Setting Range
9999
0 to 500A, 9999
9999
0 to 200%, 9999
9999
0 to 200%, 9999
9999
0 to 200%, 9999
Referenced from rated inverter current
Referenced from setting (rated motor current)
150% (180%) is the limit value.
100% is the optimum value.
The setting of 0 to 200% is the limit value.
The setting of 0 to 200% is the optimum
value.
150% (180%) is the limit value.
100% is the optimum value.
The setting of 0 to 200% is the limit value.
The setting of 0 to 200% is the optimum
value.
2Hz is the starting frequency.
The setting of 0 to 10Hz is the starting frequency.
Pr. 60 "intelligent mode selection"
Remarks
9999: Referenced from rated inverter
current.
Reference Current
Reference Current
Reference Current
Reference Current
90
PARAMETERS
Related parameter
Remarks
Shortest acceleration/deceleration mode
Optimum acceleration/deceleration mode
Shortest acceleration/deceleration mode
Optimum acceleration/deceleration mode
Remarks
Shortest acceleration/deceleration mode
Optimum acceleration/deceleration mode
Shortest acceleration/deceleration mode
Optimum acceleration/deceleration mode