Transistorized inverter
Hide thumbs Also See for FR-A520-0.4K-NA:
Table of Contents

Advertisement

No.
Item
3
Run command
Inverter status
4
monitor
Running frequency
5
write
2
(E
PROM)
6
Inverter reset
7
All clear
8
User clear
9
Parameter write
10
Parameter read
Read
Link
parameter
11
expansion
setting
Write
Read
Second
parameter
12
changing
(Code
FF = 1)
Write
Instruction
Code
H00 to HFF: Run command
b7
0
0
0
(For example 1)
HFA
[Example 1] H02
... Forward rotation
[Example 2] H00
... Stop
H00 to HFF: Inverter status monitor
b7
0
0
0
(For example 1)
[Example 1] H02
H7A
... During forward rotation
[Example 2] H80
... Stop due to alarm
*The output data depends on the Pr. 190 to Pr. 195 settings.
H0000 to H9C40: 0.01Hz increments (hexadecimal)
(0 ≠ 400.00 Hz)
HEE
To change the running frequency consecutively, write data to the
inverter RAM. (Instruction code: HED)
H9696: Resets the inverter.
As the inverter is reset on start of communication by the computer, the
HFD
inverter cannot send reply data back to the computer.
All parameters return to the factory settings.
Any of four different clear operations is performed according to the data.
Pr.
Data
H9696
HFC
H9966
H5A5A
H55AA
When all parameter clear is executed for H9696 or H9966,
communication-related parameter settings also return to the factory
settings. When resuming operation, set the parameters again.
H9669: User clear is made.
Communi-
HFC
cation Pr.
{
H80 to HE3
Refer to the data list (Appendix 1) and write and/or read parameter
values as required.
H00 to H63
Note that some parameters may not be accessible.
H00 to H6C and H80 to HEC parameter values are changed.
H00: Pr. 0 to Pr. 99 values are accessible.
H7F
H01: Pr. 100 to Pr. 159 , Pr. 200 to Pr. 231 and Pr. 900 to Pr. 905
values are accessible.
H02: Pr. 160 to Pr. 199 and Pr. 232 to Pr. 285 values are accessible.
HFF
H03: Pr. 300 to Pr. 399 values are accessible.
H09: Pr. 990 value is accessible.
When setting the programmed operation
(data code H3D to H5A, H8D to HAD)
parameter
H6C
H00: Time
H01: Time
H02: Rotation direction
When setting the bias/gain (data code H5E to H6A, HDE to HED)
parameter
H00: Offset/gain
HEC
H01: Analog
H02: Analog value of terminal
Description
b0:
b0
b1: Forward rotation (STF)
0
0
0
1
0
b2: Reverse rotation (STR)
b3:
b4:
b5:
b6:
b7:
b0: Inverter running (RUN) *
b1: Forward rotation (STF)
0
0
0
1
0
b2: Reverse rotation (STR)
b3: Up to frequency (SU) *
b4: Overload (OL) *
b5: Instantaneous power
failure (IPF) *
b6: Frequency detection (FU) *
b7: Alarm occurrence *
Communi-
Calibration
cation Pr.
×
{
{
{
×
×
×
{
Calibration
Other Pr.
×
{
121
PARAMETERS
HEC
Other Pr.
HF3
HFF
{
{
{
{
{
{
{
{
HEC
HFC
HFF
{
6 3 3 B
Time (Min.) Min. (Sec.)
Number
of Data
Digits
2 digits
2 digits
4 digits
4 digits
4 digits
4 digits
4 digits
2 digits
2 digits