1. Specifications
General
Mains voltage
Mains frequency
Power consumption
Camera supply
Weight
Dimensions (WxHxD)
High voltage (zero beam)
'Ambient temperature
- Operating
- Storage
TV system
Number of lines
Field frequency
Resolution-bandwidth
Inputs
Camera-telephone plug
CVBS- BNC plug
Audio- cinch plug
100 - 240 VAC + 10%
50 - 60 Hz
24,4 W (max.) 4 camera's
24V dc
5,7 kg
320 x 310
x 310 mm
12 kV
+10 - +45 °C
-25 - +70 °C
625 / 525 (PAL/NTSC)
50 Hz/ 60 Hz
4 MHz
2-wire twisted pair
1V,, into 75Q (VCR)
500 mV, into 10kQ (VCR)
2. Controls and Connections
Controls and connections of VSS2360/o0T & VS23605T & VS23655T (POS)
PHILIPS
:
Se
SSS]
QOoo0oo0d |
G
ver auto 1
2
3
4
|
cD
A-1
. Stand by
Auto
VCR
Contrast
Brightness
Volume
Talk
. Speaker
0. Action
ZOMNOTAYONMS
PCS 97 058 GB
Site
Camera selection 1-4
®
CL 76630015_0C7.a1
Outputs
Camera-telephone plug
CVBS- cinch plug
Audio- cinch plug
Audio
Power output
Speaker
Microphone
Frequency response
VCR signals
video input (CVBS)
audio input
video output (CVBS)
audio output
Alarm facilities
Contacts
Ratings
. Camera inputs 1-4
. Slave output
. Alarm output
. Next camera input
. Power on/off
NOORON—
Sequence time adjustment
2-wire transmission
1 V,, into 75Q (VCR & Slave)
500 mV, into 10kQ (not affected
by the volume control)
200 mW
built in 25 Q
built in, electret
baseband 30 -16000 Hz
1 V,, on 75Q
500 mV, on 10kQ
1V,, on 75Q
500 mv,, on 10 kQ (not
affected by the volume control)
Normally open or normally
closed contact.
max. switching voltage
24Vdc/24Vac
max. switching current 2A
ee
|
out
ghd in
alarm
next
cam
m
6
6 CL 766109" 5 002.8
. Audio & Video / In & outputs

Advertisement