Download Print this page

Philips VSS2360/00T Service Manual page 27

12" black & white observation system vm6
Hide thumbs Also See for VSS2360/00T:

Advertisement

CP-number:
Change Note:
Type numbers:
CP88239
AT27-06-1527
VSVSS23+22+44xx
Introduction:
OP.. 9743
Changed
Item:
Service code:
5130 from 4822 146 31412 into
4822 146 11051
3118 from 4822 116 52257 into
4822 116 52251
add:
3133 was reserved into 3R3
4822 053 11338
Reason:
improvement power delivery of the power supply
————
CP-number:
Change Note:
Type numbers:
CP88241
AT27-06-1494
VS/VSS23+22+44xx
Introduction:
OP..9747
Changed
Item:
Service code:
3814 from 4822 100 20887 into
4822 101 11908
2820 from 4822 126 12158 into
5322 121 42578
2841
idem
5322 121 42578
2845
idem
5322 121 42578
Reason:
Introduction of new "dwell time pot-meter'
Other type of the capacitors
CP-number:
Change Note:
Type numbers:
CP11704
AT27-06-1496
VSS/VS22xx+23xx
eee
Introduction:
OP..9748
Changed
Item:
Service code:
7875 pP (PCB80C51BH) version F1.0 into F1.1
4822 209 15934
Reason:
Change of the talk key functionality.
Introduction:
OP04 9816
Changed
item:
Service code:
6121 from 4822 130 34499 BZX79-C20 into BZX79-C24
4822 130 34398
(Zener was 20 Volt becomes 24 Volt)
Reason:
Due to component tolerances, some sets don't start up at low mains voltages
NS