HP 5355A Operating And Service Manual page 38

Automatic frequency converter
Hide thumbs Also See for 5355A:
Table of Contents

Advertisement

Model 5355A
Operation and Programming
Table 3-4. Offset Measurements
————
———-
MOTE
The offset measurement mode allows a constant to be added to or
subtracted from a measurement, as shown below.
STEP
PROCEDURE
RESULT
1
i
Perform the preliminary
procedures in paragraph
3-34. Set the 5345A
POWER switch to ON.
The 5355A key LEDs illuminate momentarily,
key illuminates. 5345A
displays head code momentarily. (See paragraph 3-56,} 5345A displays ail zeros.
2
Press I *
Key LED illuminates. 5345A displays -1. GHz.
NOTE
Steps 3 through 9 show how to expand the number of digits in the
display, position the decimal point and select displayed resolution for
;
precise offset frequencies, if these procedures are understood, proceed
to step 10.
3
Press
f7||
5345A display changes from -1, to -1.00 GHz.
4
Repeat step 3 four
more times
5345A display adds two zeros eacn time key is pressed (for a total of 10 zeros;.
s
press Q'i-
Key LED illuminates. Decimal point moves one place to right.
6
Repeat step 5
Same as- step 5.
Repeat step 5
Decimal point moves two places to left.
8
press (Tjj
5345A display changes from GHz to MHz,
9
Repeat step 8 five
more times.
5345A display changes from MHz to kHz, Hz, mHz, p.Hz, and i>ade to GHz, in
that order.
10
Using procedures
described in steps
3 through 9, select
desired offset frequency.
5345A displays offset frequency.
11
Apply signal to be
measured to RF HEAD
INPUT, then
Key LED extinguishes. 5345A displays input signal.
press PS
1
--SJ
12
Press 01-
Key LED illuminates. 5345A displays resultant frequency.
3-16

Advertisement

Table of Contents
loading

This manual is also suitable for:

5356a5356b5356c

Table of Contents