When The Warning Lamp Is Lighted - Panasonic DVCPRO AJ-DE77P Operating Instructions Manual

Non-linear editing system
Hide thumbs Also See for DVCPRO AJ-DE77P:
Table of Contents

Advertisement

Error Items
When the AUTO OFF lamp is lighted
hen there is no response from the servo micrcomputer for 1 or more seconds, | STOP
the AUTO OFF lamp lights.
(POWER OFF — ON)
When only the servo microcomputer was reset in an instantaneous power failure, | STOP
the AUTO OFF lamp lights.
(POWER OFF — ON)
If the start/end processing operation is not completed, the AUTO OFF lamp lights.
| STOP
(POWER OFF — ON)
If the supply reel motor should rotate at an abnormally fast rate, the AUTO OFF | STOP
lamp lights.
(POWER OFF — ON)
If an abnormal torque applied to the supply reel motor is detected or if an abnormal | STOP
current flowing to the current-sensing resistor is detected, the AUTO OFF lamp | (POWER OFF — ON)
lights.
If the take-up reel motor should rotate at an abnormally fast rate, the AUTO OFF; STOP
lamp lights.
(POWER OFF — ON)
If an abnormal torque applied to the take-up reel motor is detected, the AUTO OFF | STOP
lamp lights
(POWER OFF — ON)
If the tape has not been wound up during unloading, the AUTO OFF lamp lights.
STOP
(POWER OFF — ON)
If, after the total tape amount has been detected, the amount of tape wound up on| STOP
the take-up reel and the amount of tape supplied by the supply reel differ to an
(POWER OFF — ON)
abnormal extent while the tape is traveling in the forward or reverse direction, the
AUTO OFF lamp lights.
lf, after the cassette has been inserted, the tape take-up reel has not wound up the | STOP
tape while the total tape amount is not detected and while the tape is traveling in (POWER OFF -+ ON)
the forward or reverse direction, the AUTO OFF lamp lights.
When the loading operation is performed while the cassette lid is not open, the| STOP
AUTO OFF lamp lights.
(POWER OFF — ON)
When the WARNING lamp is lighted
ee
Siehe O
When it is detected that the fan motor has stopped operating, the WARNING lamp | Check the fan motor.
If the fan motor has stopped
operating, restart it.
When it is detected that the servo lock has become disengaged while the tape is} Check the status of the
traveling during x4 speed tape playback, the WARNING lamp lights.
tape recording.
When an unrecorded part is played while the tape is traveling during x4 speed tape|Check the status of the
playback, the WARNING lamp lights.
tape recording.

Advertisement

Table of Contents
loading

Table of Contents