Advertisement

Quick Links

EN83CTLA SNMP Card
User Manual
Issue
04
Date
2024-01-30
HUAWEI DIGITAL POWER TECHNOLOGIES CO., LTD.

Advertisement

Table of Contents
loading

Summary of Contents for Huawei EN83CTLA

  • Page 1 EN83CTLA SNMP Card User Manual Issue Date 2024-01-30 HUAWEI DIGITAL POWER TECHNOLOGIES CO., LTD.
  • Page 2 Notice The purchased products, services and features are stipulated by the contract made between Huawei Digital Power Technologies Co., Ltd. and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS"...
  • Page 3: About This Document

    About This Document About This Document Purpose This document describes the EN83CTLA SNMP card in terms of its features, appearance, structure, installation, usage, and operations. The EN83CTLA SNMP card is an optional communications card designed for the UPS2000-H-(6 kVA–20 kVA), UPS2000-G-(6 kVA–20 kVA), and UPS2000-H-(6 kVA–10 kVA) series.
  • Page 4 Adapted the SNMP card to the UPS2000- H-(6 kVA–20 kVA) series. Updated 2.2 Port Description. 2022-11-03 Adapted the SNMP card to the UPS2000- G-(6 kVA–20 kVA) series. 2021-08-03 This issue is the first official release. Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 5: Table Of Contents

    4.4.4 Battery System................................... 21 4.5 Query......................................22 4.6 System Settings..................................22 4.6.1 Site Configuration................................23 4.6.2 System Time..................................23 4.6.3 Comm. Settings.................................. 24 4.6.4 Alarm Parameters................................26 4.6.5 SNMP..................................... 26 Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 6 5.5.1 Software Description................................ 42 5.5.2 Applying for Access Rights............................. 42 5.5.3 Monitoring the UPS................................46 5.6 Managing the UPS by Using the NMS Complying with Huawei Standard............46 5.6.1 SNMP Card Versions................................. 46 5.6.2 Installing the UPS MIB Library............................46 5.6.3 Managing the UPS by Using the NMS........................
  • Page 7: Safety Information

    Wear electrostatic discharge (ESD) gloves when you install the SNMP card. Change the preset password in your first login to the web user interface (WebUI) of the SNMP card. For details, see section User Management. Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 8: Product Description

    Supports the SNMP, HTTPS, and SSH protocols. ● Supports the SNMP agent v1, v2c, and v3 protocols. The HUAWEI_UPS_MIB and HUAWEI-MIB libraries can be downloaded from the built-in web page and do not need to be installed using a CD-ROM. ●...
  • Page 9: Port Description

    Table 2-1 Port function Silk Screen Name Indicator Function USB port Supports a 4G module. TEM_HUM Port for a Connects to an ambient T/H southbound sensor. device RS485 Reserved southbound port Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 10 NMS access is not supported. Figure 2-2 TEM_HUM port Table 2-2 TEM_HUM port signal definition Component Signal Port Type Location RS485+ RJ45 RS485– Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 11 2 Product Description Component Signal Port Type Location 12V_OUT RS485+ RS485– Figure 2-3 COM port Table 2-3 COM port signal definition Component Signal Port Type Location RS485_2+ RJ45 RS485_2- RS485+ RS485– Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 12: Installation And Basic Settings

    SNMP card, preventing ESD from damaging the SNMP card. Hold the edges of the SNMP card when you move or install it. Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 13: Installing The Snmp Card

    3 Installation and Basic Settings 3.3 Installing the SNMP Card The SNMP cards for Huawei UPSs can be installed in the same way. They need to be installed behind the optional card slot cover labeled INTELLISLOT on the rear panel of the UPS. The actual installation position may vary with product models.
  • Page 14: Installing Optional Components

    Step 1 Connect the RJ45 terminal at one end of a cable to the TEM_HUM port on the ambient T/H sensor of the SNMP card, and connect the other end to the RJ485-IN port on the ambient T/H sensor. Figure 3-4 Installing an ambient T/H sensor Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 15 RJ45 Terminal on RJ45 Terminal RJ45 Terminal RJ45 Terminal on the SNMP Card Signal on the Signal on the T/H the T/H Sensor SNMP Card Sensor X1.1 RS485+ RS485_T+ X2.1 Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 16: Module

    4G module can report alarms and signals to the network management device (cloud NMS) in wireless mode. Figure 3-7 4G module (1) Indicator (2) SIM card (3) Module installation (4) Base installation position port Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 17 Step 3 Connect the 4G module to the USB port of the SNMP card using a USB2.0 extension cable. Install the magnetic 4G module on the nearby cabinet. Figure 3-9 Installing a 4G module Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 18: Setting An Ip Address For The Snmp Card

    Modify the settings based on the network segment that the UPS belongs to. Procedure Step 1 Press on the UPS control panel to enter the main menu, and choose Settings. Step 2 Enter the password (the preset password is 000001). Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 19: Setting An Ip Address On The Ups2000-H App

    Step 2 Tap Configuration. Step 3 Select Optional Card Settings. Step 4 On the Optional Card Settings screen, set SNMP card IP address, SNMP card subnet mask, and SNMP card gateway. Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 20: Setting An Ip Address On The Ups2000-G/Ups2000-H Webui

    Step 1 Log in to the WebUI. For details, see section 4.2 "Logging In to the WebUI." Step 2 Click System Settings. Step 3 Choose Comm. Settings. Step 4 In the IP Settings area, set IP address, Subnet mask, and Gateway. Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 21 EN83CTLA SNMP Card User Manual 3 Installation and Basic Settings Figure 3-11 IP Settings ----End Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 22: Webui

    Step 3 Enter https:// language, and enter the correct User Name and Password. The default user name is admin, and the preset password is Changeme. Figure 4-1 Logging in to the WebUI Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 23 ● There is no verification code needed on the login page by default. After three login failures, a verification code is required. ● If you enter incorrect passwords for five consecutive times, the account will be locked out for 5 minutes. ----End Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 24: Menu Structure

    4 WebUI 4.2 Menu Structure Figure 4-2 Menu structure 4.3 Home System Overview Choose Home > System Overview to view the running status of the mains, bypass, batteries, and output. Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 25: Monitoring

    Choose Home > Active Alarm to view the active alarms of the system. Figure 4-4 Active Alarm 4.4 Monitoring 4.4.1 Amb. T/H Sensor Summary Choose Monitoring > Amb. T/H Sensor Summary to view the Running Information of the ambient T/H sensor. Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 26: Wireless Module

    Choose Monitoring > UPS System to view the Running Information of the UPS system. Figure 4-8 Running Information Choose Monitoring > UPS System > Running Parameter to set the overtemperature, undertemperature, overhumidity, and underhumidity alarm thresholds. Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 27: Battery System

    Choose Monitoring > UPS System > Running Control to perform Running Control for the UPS system. Figure 4-10 Running Control 4.4.4 Battery System Choose Monitoring > Battery System to view the Running Information of the ESMs. Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 28: Query

    Query the performance data of the components related to the Data system. Export Data Choose Historical Alarm, Active Alarm, Operation Log, and Performance Data to export the corresponding information about the system. 4.6 System Settings Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 29: Site Configuration

    Select the network security Upload the key of the network security certificate. certificate key to be uploaded Export certificate file: Export the root certificate. 4.6.2 System Time Figure 4-14 System Time Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 30: Comm. Settings

    (Optional) Select NTP Server Synchronization to synchronize time from the NTP server. 4.6.3 Comm. Settings Figure 4-15 Comm. Settings Table 4-5 IP Settings Item Description Default Value Value Range IP type IPv4 IPv4, IPv6 Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 31 Enable access the UPS with a terminal tool. Disable: The SSH port is disabled and cannot be accessed. Enable: The SSH port is enabled and can be accessed. Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 32: Alarm Parameters

    NetEco are enabled. Enable: All functions are available. 4.6.4 Alarm Parameters Enables or disables alarm information for components in the system. Figure 4-16 Alarm Parameters 4.6.5 SNMP Figure 4-17 SNMP Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 33: Event Notification

    After the Event Notification information is configured, alarms will be sent to the configured mailbox. NO TE For details about how to configure the Event Notification, see 5.3 Configuring Email Notification. Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 34: Outbox Configuration

    NO TE For details about how to configure the outbox, see 5.3 Configuring Email Notification. 4.6.8 IP Whitelist Configuration Sets the range of IP addresses that can access the WebUI. Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 35: Cloud Nms

    Upload a local certificate file. certificate file Upload key file Key file of the certificate. Key password Decryption password of the key. Confirm key Confirm the decryption password of the key. password Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 36: Maintenance

    Import and export system configuration files. File User Allow users to perform Add, Modify, Delete, Lock, and Unlock Management operations, and set passwords. Fault Export fault information. Information BSP Upgrade Upgrade the BSP version. Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 37: Device Commissioning

    Choose Monitoring > UPS System > Running Control and select Inv. ON or Inv. OFF based on site requirements. ----End 5.2 Setting the Ambient T/H Sensor Prerequisites Cables have been connected to the T/H sensor. Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 38 Set the address of the device connected to the UPS2000 to 1 (DIP switch 1 on ENR1DETA MODULE is set to ON and other DIP switches are set to OFF) and the default baud rate to 9600. Only one ambient T/H sensor is supported. Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 39: Configuring Email Notification

    Set Address type to Domain name. Set the address type based on site requirements. To configure the IP address of the DNS server, choose System Settings > Comm. Settings. Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 40 Enter the outbox address. Set User authentication for mailbox server login. The default value is Enable. Enter the user name and password of the outbox or the mailbox authorization password. Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 41 Mailbox Certificate area. NO TE The following mailbox addresses are for reference only (the actual parameters may vary) and are used only for configuring the email function. Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 42 Step 3 Choose System Settings > Event Notification. On the Mailbox Settings page, you can add a mailbox address for receiving notifications. NO TE The mailbox address is used only for configuring the email function. Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 43 Set Alarm notification delay, Time of the first reminder, and Interval, and add alarm notification based on site requirements. Figure 5-6 Setting alarm notification parameters Figure 5-7 Adding alarm notification Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 44: Setting The 4G Module And Cloud Nms

    Step 1 Log in to the WebUI. For details, see 4.1 Logging In to the WebUI. Step 2 Choose Monitoring > Wireless Module > Running Parameter > Basic Parameters, and set Mobile data to Enable. Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 45 Confirm DES/AES Password. Authentication Privacy Protocol Remarks Protocol SHA1 AES-128 MD5, SHA1, and DES are insecure protocols. SHA2-256, SHA2-384, SHA2-256 AES-192 SHA2-512, AES-128, AES-192, and AES-256 are recommended. SHA2-384 AES-256 SHA2-512 Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 46 Note that MD5/SHA password and DES/AES password must be set to different values. Record the settings. After setting the parameters, click Confirm. Click Add under SNMP Trap. Figure 5-13 Adding SNMP trap Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 47 Step 5 Choose System Settings > Cloud NMS and set Cloud NMS to Enable. Figure 5-14 Setting the cloud NMS Step 6 Setting the NMS IP address Figure 5-15 Setting the IP address Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 48: Managing The Ups By Using The Neteco 1000U

    It can manage the performance data and alarm information of the UPS remotely and in real time. This improves the UPS centralized management and remote operation and maintenance. NO TE You can download the software from Huawei official website https://support.huawei.com or https://support.huawei.com/enterprise. 5.5.2 Applying for Access Rights Prerequisites ●...
  • Page 49 Set this parameter based on the IP Settings mask subnet mask assigned by the network administrator. Default 192.168.8.1 Set this parameter based on the gateway default gateway address assigned by the network administrator. Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 50 Confirm DES/AES Password. Authentication Privacy Protocol Remarks Protocol SHA1 AES-128 MD5, SHA1, and DES are insecure protocols. SHA2-256, SHA2-384, SHA2-256 AES-192 SHA2-512, AES-128, AES-192, and AES-256 are recommended. SHA2-384 AES-256 SHA2-512 Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 51 Set Trap Target Address and Trap Port, set SNMP Version to SNMPv3, and specify SNMPv3User Name. Set Trap Target Address to the IP address of the NMS server and set Trap Port to the port defined by the user. Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 52: Monitoring The Ups

    The MIB library is located in the SNMP card. SnmpMib.RAR contains two MIB files: HUAWEI-MIB.mib and HUAWEI_UPS_MIB.mib. When loading the MIB library to the NMS, load the HUAWEI-MIB.mib file first, and then load the HUAWEI-UPS-MIB.mib file. For details, see the NMS user manual.
  • Page 53: Applying For Access Rights

    Procedure Step 1 Apply for a fixed IP address from the equipment room network administrator. Step 2 Set the IP address, subnet mask, and default gateway on the WebUI. Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 54 Confirm DES/AES Password. Authentication Privacy Protocol Remarks Protocol SHA1 AES-128 MD5, SHA1, and DES are insecure protocols. SHA2-256, SHA2-384, SHA2-256 AES-192 SHA2-512, AES-128, AES-192, and AES-256 are recommended. SHA2-384 AES-256 SHA2-512 Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 55 Set Trap Target Address and Trap Port, set SNMP Version to SNMPv3, and specify SNMPv3User Name. Set Trap Target Address to the IP address of the NMS server and set Trap Port to the port defined by the user. Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 56: Managing The Ups

    After setting the parameters, click Confirm. ----End 5.6.3.2 Managing the UPS Step 1 Load the downloaded MIB library. Select HUAWEI-MIB.mib or HUAWEI_UPS_MIB.mib. Step 2 Set the NMS software parameters and enter the UPS IP address in the NMS software to connect the NMS software to the UPS.
  • Page 57: Troubleshooting

    Check the browser version and the SNMP card IP address that you have entered in the address box. SNMP card problems If the fault persists after the preceding checks, replace the SNMP card with a new one. Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 58: A Acronyms And Abbreviations

    RJ45 Registered Jack 45 RS485 Recommended Standard 485 secure hash algorithm SNMP Simple Network Management Protocol Secure Shell Secure Sockets Layer Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.
  • Page 59 EN83CTLA SNMP Card User Manual A Acronyms and Abbreviations state of charge state of health TCP/IP Transmission Control Protocol/Internet Protocol uninterruptible power system Issue 04 (2024-01-30) Copyright © Huawei Digital Power Technologies Co., Ltd.

Table of Contents