ELECTRICAL AND CONTROL SETTINGS

Split system - Indoor unit
YUTAKI S
Model
Power supply
RWM-(2.0-3.0)NRE(-W)
1~ 230V 50Hz
1~ 230V 50Hz
RWM-(4.0-6.0)NE(-W)
3N~ 400V 50Hz
RWM-(8.0/10.0)NE(-W)
3N~ 400V 50Hz
?
N O T E
The data corresponding to DHW tank heater is calculated in combination with the domestic hot water tank accessory "DHWT-(200/300)S-3.0H2E".
YUTAKI S COMBI
Model
Power supply
RWD-(2.0-3.0)NRW(S)
1~ 230V 50Hz
E-(200/260)(-K)(-W)
1~ 230V 50Hz
RWD-(4.0-6.0)NW(S)
E-(200/260)S(-K)(-W)
3N~ 400V 50Hz
54
PMML0510 rev.1 - 10/2019
Applicable voltage
U max.
U min.
(V)
(V)
Without electric heaters
With electric heater
253
207
With DHW tank heater
With electric and DHW tank heaters
Without electric heaters
With electric heater
253
207
With DHW tank heater
With electric and DHW tank heaters
Without electric heaters
With electric heater
440
360
With DHW tank heater
With electric and DHW tank heaters
Without electric heaters
With electric heater
440
360
With DHW tank heater
With electric and DHW tank heaters
Applicable voltage
U max.
U min.
(V)
(V)
Without electric heaters
With electric heater
253
207
With DHW tank heater
With electric and DHW tank heaters
Without electric heaters
With electric heater
253
207
With DHW tank heater
With electric and DHW tank heaters
Without electric heaters
With electric heater
440
360
With DHW tank heater
With electric and DHW tank heaters
Operation mode
Operation mode
MC
CB
ELB
(A)
(A)
(nº of poles/A/mA)
0.2
5
14.6
16
2/40/30
14.6
16
28.9
32
0.3
5
29.0
32
2/40/30
14.7
16
43.4
50
2/63/30
0.3
5
9.9
15
4/40/30
14.7
15
24.2
25
0.6
5
14.9
20
4/40/30
15.0
15
29.2
30
MC
CB
ELB
(A)
(A)
(nº of poles/A/mA)
5
0.2
16
14.6
2/40/30
16
12.7
32
27.1
0.3
5
29.0
32
2/40/30
12.8
16
41.5
50
2/63/30
0.3
5
9.9
15
4/40/30
12.8
15
22.4
25

Hide quick links:

Advertisement

Table of Contents
loading