If input power to PA is low it is most likely a problem with the TransAAM U500.
-
If input power to PA is ok it is most likely a problem with the PA
If output power
EGSM_OUT
U001
(do a visual check for misplaced parts around FEM U001).
GSM TX signals:
-
TX_LB_IN
-
IPC_BCM: mode switch between GMSK and EDGE. Currently BCM is associated
with GMSK mode and should be logic 0. In EDGE mode, IPC mode is selected and
should be logic 1:
-
TX_LB_HB_IN: mode switch between LB and HB. LB is logic 0 and HB logic 1
-
VRAMP: voltage that controls PA operation. If probed with an oscilloscope, you will
see signals close to a rectangular pulse of value 1.8V to 2.2V for max power output
-
PAC_DET: power detector with voltage reading corresponds to VRAMP value
-
TX_EN: logic signal that enables the PA
-
GSM_TCXO: 26MHz clock for TransAAM
TX Supply voltages
-
VRF_TX_2_775V
-
BATT+
-
LVDD
-
JVDD
-
QVDD_1_8
-
VDDA_2_7
-
VDDA_CP_2_7
-
VDD_ACE_2_7
-
VDD_TXRX_2_7
Repair Support Information
from PA is good the trouble is most likely related to a bad FEM
and TX_HB_IN: modulated input TX signal from TransAAM
Doc. No:
Version:
Date:
Page:
© Copyright 2003-2007 Motorola Inc. All Rights reserved.
Motorola internal use
TSG_3G_V6
1.0
23.07.2007
35 / 40
U800
itself.