If an accident (including but not limited to the following) occurs on the site,
ensure the safety of onsite personnel first and contact the Company's service
engineers.
Battery Falling or Strong Impact
Flood
Fire Alarm Horn/Strobe
When the alarm indicator on the equipment blinks or buzzes:
Issue 15 (2023-11-01)
12
If a battery has obvious damage or abnormal odor, smoke, or fire occurs,
evacuate the personnel immediately, call emergency services, and contact the
professionals. The professionals shall use fire extinguishing facilities to
extinguish the fire under safety protection.
If the appearance is not deformed or damaged, and there is no obvious
abnormal odor, smoke, or fire, ensure safety and perform the following
operations:
Warehouse: Evacuate personnel, transfer the battery to an open and safe
place by professionals using mechanical tools, and contact the Company's
service engineers. Leave the battery for an hour and ensure that the
battery temperature is within the room temperature range (tolerance:
±10°C) before handling.
ESS onsite: Evacuate personnel, close the doors of the ESS, transfer the
battery to an open and safe place by professionals using mechanical
tools, and contact the Company's service engineers. Leave the battery for
an hour before handling.
Power off the system if it is safe to do so.
If any part of the batteries is submerged in water, do not touch the batteries
to avoid electric shock.
Do not use batteries that have been soaked in water. Contact a battery
recycling company for disposal.
Do not approach.