Table 1-13. Server Module Messages (continued)
Message
Memory address line
failure at address , read
value expecting value
Memory double word logic
failure at address , read
value expecting value
Memory odd/even logic
failure at start address
to end address
Memory write/read failure
at address , read value
expecting value
Memory mirroring enabled
Memory tests terminated by
keystroke
No boot device available
No boot sector on
hard-disk drive
No timer tick interrupt
Not a boot diskette
PCI BIOS failed to install Faulty or improperly installed.
38
About Your System
Causes
Faulty or improperly installed memory
modules, or faulty server module
board.
Memory mirroring enabled
The spacebar was pressed during
POST to terminate the memory test.
Faulty or missing diskette drive,
optical drive, or hard drive.
An operating system is not on the
hard drive.
Faulty server module board.
Not a bootable diskette.
Corrective Actions
Ensure that all memory modules are
properly installed. See "Troubleshooting
Server Module Memory" on page 112. If
the problem persists, see "Getting Help"
on page 127.
Information only.
Information only.
Check the Integrated Devices
configuration settings in the System
Setup program and ensure that the
controller for the boot device is enabled.
See "Using the System Setup Program"
on page 43. Ensure that the controller
for the boot device is enabled.
If the problem persists, replace the drive.
See "Hard Drives" on page 89.
Check the hard-drive configuration
settings in the System Setup program.
See "Using the System Setup Program"
on page 43.
See "Getting Help" on page 127.
Use a bootable diskette.
Reseat the daughter card. See "I/O
Module Daughter Card" on page 82. If
the problem persists, see "Getting Help"
on page 127.