Dell 1955 Hardware Owner's Manual page 39

Dell poweredge 1955 servers: user guide
Hide thumbs Also See for 1955:
Table of Contents

Advertisement

Table 1-13. Server Module Messages (continued)
Message
Plug & Play Configuration
Error
Read fault
Remote Configuration
update attempt failed
Sector not found
Seek error
Seek operation failed
Shutdown failure
Spare bank enabled
The amount of system
memory has changed.
Time-of-day clock stopped
Time-of-day not set -
please run SETUP program
Timer chip counter 2
failed
Causes
Error encountered in initializing PCI
device; faulty server module board.
Faulty diskette, diskette drive, optical
drive, or hard drive.
Server module could not implement
Remote Configuration request.
Faulty diskette or hard drive.
Shutdown test failure.
Memory sparing enabled.
Faulty memory module.
Information only, if you have changed
the memory configuration.
Faulty battery; faulty server module
board.
Incorrect Time or Date settings; faulty
server module board battery.
Faulty server module board.
Corrective Actions
Set the NVRAM_CLR switch to "on"
and reboot the server module. See
Figure 6-2 for switch location.
Check for a BIOS update. If the problem
persists, see "Getting Help" on page 127.
Replace the diskette. Ensure that the
custom cable is properly connected. See
"Troubleshooting USB Devices" on
page 105 or "Troubleshooting Hard
Drives" on page 113. for the appropriate
drive(s) installed in your system.
Retry Remote Configuration.
Replace the diskette. If the problem
persists, see "Troubleshooting Hard
Drives" on page 113 for the appropriate
drive installed in your system.
Ensure that all memory modules are
properly installed. See "Troubleshooting
Server Module Memory" on page 112. If
the problem persists, see "Getting Help"
on page 127.
Information only.
See "Troubleshooting Server Module
Memory" on page 112. If the problem
persists, see "Getting Help" on page 127.
See "Troubleshooting Server Module
Memory" on page 112. If the problem
persists, see "Getting Help" on page 127.
Check the Time and Date settings. See
"Using the System Setup Program" on
page 43. If the problem persists, see
"Troubleshooting the Server Module
Battery" on page 115.
See "Getting Help" on page 127.
About Your System
39