Hitachi CP-SX12000 User Manual page 64

Hitachi cp-sx12000: user guide
Hide thumbs Also See for CP-SX12000:
Table of Contents

Advertisement

SECURITY menu
Item
TRANSITION
DETECTOR
(continued on next page)
64
If this function is set to ON when the vertical angle of
the projector or mirror setting at which the projector is
turned on is different than the previously recorded, the
TRANSITION DETECTOR ON alarm will be displayed
and the projector will not display the input signal.
• To display the signal again, set this function OFF.
• After about 5 minutes of displaying the TRANSITION DETECTOR ON alarm,
the lamp will turn off.
• Keystone adjustment feature has been prohibited as long as the Transition
Detector function is on.
1 Turning on the TRANSITION DETECTOR
1-1 Use the ▲/▼ buttons on the SECURITY menu to
select TRANSITION DETECTOR and press the ►
or the ENTER button to display the TRANSITION
DETECTOR on/off menu.
1-2 Use the ▲/▼ buttons on the TRANSITION
DETECTOR on/off menu to select ON. Select
ON and the current angle and mirror setting will
be recorded. The ENTER NEW PASSWORD
box (small) will be displayed.
1-3 Use the ▲/▼/◄/► buttons to enter a password.
Move the cursor to the right side of the ENTER
NEW PASSWORD box (small) and press the ►
button to display the NEW PASSWORD AGAIN
box, enter the same password again.
1-4 Move the cursor to the right side of the NEW
PASSWORD AGAIN box and press the ►
button to display the NOTE NEW PASSWORD
box for about 20 seconds, please make note of
the password during this time.
• Pressing the ENTER button on the remote control or the ► button on
the projector will return to the TRANSITION DETECTOR on/off menu.
• Please do not forget your TRANSITION DETECTOR password.
• This function will activate only when the projector is started after the power
switch was turned off.
• This feature may not function properly if the projector is not in a stable position
when ON is selected.
2 Turning off the TRANSITION DETECTOR
2-1 Follow the procedure in 1-1 to display the Transition Detector on/off menu.
2-2 Select OFF to display the ENTER PASSWORD box (large). Enter the
registered password and the screen will return to the TRANSITION
DETECTOR on/off menu.
If an incorrect password is input, the menu will close. If necessary, repeat
the process from 2-1.
3 If you have forgotten your password
3-1 Follow the procedure in 1-1 to display the Transition Detector on/off menu.
3-2 Select OFF to display the ENTER PASSWORD box
(large). The 10 digit Inquiring Code will be displayed
inside the box.
3-3 Contact your dealer with the 10 digit Inquiring
Code. Your password will be sent after your
user registration information is confirmed.
Description