HP 108164-003 - ProLiant - 800 Reference Manual page 119

Microsoft windows event id and snmp traps reference guide for use with smartstart version 8.25
Table of Contents

Advertisement

cpqRackServerBladePosition
cpqRackServerBladeSparePartNumber
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: "Server blade [cpqRackServerBladeName] inserted into position
[cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack
[cpqRackName]."
NT Event ID: 1172 (Hex)0x84350494 (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Rack Power Subsystem Not Load Balanced
Log Message: The power subsystem is out of balance for this power enclosure.
SNMP Trap: cpqRackPowerChassisNotLoadBalanced - 22030 in CPQRACK.MIB
Symptom: Power subsystem not load balanced. The power subsystem is out of balance for this power
enclosure.
User Action: Check the power enclosure and power supplies. Replace any failed or degraded power
supplies. Add additional power supplies if needed.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackCommonEnclosureName
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureSparePartNumber
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: "Power subsystem not load balanced in enclosure
[cpqRackCommonEnclosureName], in rack [cpqRackName]."
NT Event ID: 1173 (Hex)0x84350495 (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Power Subsystem DC Power Problem
Log Message: There is a power subsystem DC power problem for this enclosure.
SNMP Trap: cpqRackPowerChassisDcPowerProblem - 22031 in CPQRACK.MIB
Symptom: Power subsystem DC power problem. There is a power subsystem DC power problem for
this power enclosure.
User Action: Check the power enclosure and power supplies. Replace any failed or degraded power
supplies.
Supporting SNMP Trap Data: