sysName
•
cpqHoTrapFlags
•
cpqScsiPhyDrvStatus
•
cpqScsiPhyDrvCntlrIndex
•
cpqScsiPhyDrvBusIndex
•
cpqScsiPhyDrvIndex
•
cpqScsiPhyDrvVendor
•
cpqScsiPhyDrvModel
•
cpqScsiPhyDrvFWRev
•
cpqScsiPhyDrvSerialNum
•
cpqScsiPhyDrvOsName
Supporting SNMP Trap Description: "Status is now [cpqScsiPhyDrvStatus]."
NT Event ID: 1075 (Hex)0x84350433 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Fan Status Change.
Log Message: The %6 %7 storage system connected to SCSI bus %5 of the controller in slot %4 has a
new status of %2.
SNMP Trap: cpqSs3FanStatusChange - 8008 in CPQSTSYS.MIB
Symptom: Storage System fan status change. The agent has detected a change in the Fan Status of a
storage system. The variable cpqSsBoxFanStatus indicates the current fan status.
User Action: If the fan status is degraded or failed, replace any failed fans.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqSsBoxFanStatus
Supporting SNMP Trap Description: "Storage System fan status changed to [cpqSsBoxFanStatus]."
NT Event ID: 1076 (Hex)0xc4350434 (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: Storage System Temperature Failure.
Log Message: The %6 %7 storage system connected to SCSI bus %5 of the controller in slot %4 has a
failed temperature status. Shut down the storage system as soon as possible.
SNMP Trap: cpqSs3TempFailed - 8009 in CPQSTSYS.MIB
Symptom: Storage System temperature failure. The agent has detected that a temperature status has
been set to failed. The storage system is shut down.
User Action: Shut down the storage system as soon as possible. Insure that the storage system
environment is being cooled properly and that no components are overheated.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqSsBoxTempStatus
Storage agents 37