Automatic Data Recovery (Rebuild); Time Required For A Rebuild - HP AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive Maintenance And Service Manual

Modular smart array
Hide thumbs Also See for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive:
Table of Contents

Advertisement

• When RAID 6 (ADG) is used, two drives can fail simultaneously (and be replaced simultaneously)
without data loss.
• If the offline drive is a spare, the degraded drive can be replaced.
Do not remove a failed second hard drive from an array until the first failed or missing hard drive has
been replaced and the rebuild process is complete. (When the rebuild is complete, the online LED
on the front of the hard drive stops blinking.)
Exceptions:
• In RAID 6 (ADG) configurations, any two drives in the array can be replaced simultaneously.
• In RAID1+0 configurations, any drives that are not mirrored to other removed or failed drives can be
simultaneously replaced offline without data loss.

Automatic data recovery (rebuild)

When you replace a hard drive in an array, the controller uses the fault-tolerance information on the
remaining drives in the array to reconstruct the missing data (the data that was originally on the replaced
drive) and write it to the replacement drive. This process is called automatic data recovery, or rebuild. If
fault tolerance is compromised, this data cannot be reconstructed and is likely to be permanently lost.
If another hard drive in the array fails while fault tolerance is unavailable during rebuild, a fatal system
error may occur, and all data on the array is then lost. In exceptional cases, however, failure of another
drive need not lead to a fatal system error. These exceptions include:
Failure after activation of a spare drive.
Failure of a drive that is not mirrored to any other failed drives (in a RAID 1+0 configuration).
Failure of a second drive in a RAID ADG configuration.

Time required for a rebuild

The time required for a rebuild varies considerably, depending on several factors:
The priority that the rebuild is given over normal I/O operations (you can change the priority setting
through the Array Configuration Utility (ACU) or MSA Command Line Interface (MSA-CLI).
The amount of I/O activity during the rebuild operation
The rotational speed of the hard drives
The availability of drive cache
The brand, model, and age of the drives
The amount of unused capacity on the drives
The number of drives in the array (for RAID 5 and RAID ADG)
Allow approximately 15 minutes per gigabyte for the rebuild process to be completed. This figure is
conservative, and newer drive models usually require less time to rebuild.
System performance is affected during the rebuild, and the system is unprotected against further drive
failure until the rebuild has finished. Therefore, replace drives during periods of low activity when possible.
CAUTION:
If the Online LED of the replacement drive stops blinking and the amber Fault LED glows, or if other drive
LEDs in the array go out, the replacement drive has failed and is producing unrecoverable disk errors.
Remove and replace the failed replacement drive.
When automatic data recovery has finished, the Online LED of the replacement drive stops blinking
and begins to glow steadily.
If ADR process aborts, restart the storage system and allow ADR to begin again. If ADR fails again,
back up all data on the system, do a surface analysis (using your diagnostics utility), and restore the
data from backup.
100
Hard drive failures and faulted LUNs

Advertisement

Table of Contents
loading

Table of Contents