Installing The Controller; Verifying Proper Operation - HP AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive Maintenance And Service Manual

Modular smart array
Hide thumbs Also See for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive:
Table of Contents

Advertisement

Installing the controller

1.
Insert the new or serviced array controller into the MSA chassis controller bay (1).
2.
Push the controller in as far as it will go, making sure that the controller is seated, and then press the
latch handle inward until it is flush against the front panel (2).
3.
If necessary, power on the MSA as instructed in
the
MSA.
NOTE:
Each time a system with two controllers is powered on or restarted, or if a second controller is
hot-plugged into a single-controller configuration, the firmware versions on the controllers are compared.
If the firmware versions on the two controllers are not the same, the controller LCD panel prompts to clone
the firmware from the controller with the latest version onto the other controller. For information, see
Cloning controller

Verifying proper operation

After replacing the array controller, controller cache module, or cache module battery pack, verify that:
The controller Heartbeat LED is blinking.
The controller Fault LED is off.
No new error messages are displayed on the array controller LCD display panel.
After installing a new array controller, verify that the latest available firmware is installed. See
controller firmware
• Determining the currently-installed firmware version
• Updating controller firmware
• Cloning controller firmware
• Recovering corrupted firmware
84
Customer replaceable components
2
firmware.
for the following instructions:
1
15493
Connecting the Power
and
Applying power to
Array

Advertisement

Table of Contents
loading

Table of Contents