Message
511 FIBRE CHANNEL
SUBSYSTEM HARDWARE
FAILURE
513 UNCORRECTED ECC
MEMORY ERROR SEEN
514 FIBRE SWITCH
HARDWARE FAILURE
515 FIBRE DEVICE
HARDWARE FAILURE
516 FIBRE SUBSYSTEM
LINK FAILURE
517 FIBRE SUBSYSTEM
LINK OK
58
LCD panel and message descriptions
Type
Description
Error
The array controller's Fibre
Channel subsystem has
encountered a critical
error during the power up
sequence.
Error
The array controller has
detected an uncorrectable
error in the ECC memory on
the memory cache board.
Error
The embedded switch in the
Fibre Channel I/O bay is
not responding correctly or
is not working. (Please note
that some switches take
several minutes to start up.)
Error
The array controller
firmware does not
recognize the device in
the Fibre Channel I/O bay.
The device has failed or
is not supported by the
installed firmware version.
Error
The controller is not currently
linked to anything. This
could be due to the
following:
The Fibre Channel cable
is not connected.
The device to which it
is connected is currently
not working.
The MSA is connected
to a device that with an
incompatible port type.
Informational
The Fibre Channel port has
transitioned to an online
state.
Action
Remove the failed array
controller and its associated
Fibre Channel module,
reseat the Fibre Channel
daughter card on the array
controller, wait 10 seconds,
then reinsert the Fibre
Channel module and the
array controller, ensuring
that they are fully seated in
their respective bays in the
chassis.
Should the issue persist,
contact HP support.
Remove the failed array
controller and replace the
memory cache board with a
new one.
Remove the embedded
switch, wait 10 seconds,
and then reinsert the switch,
ensuring that it is fully seated
in the chassis.
Should the issue persist,
contact HP support.
If the device was not recently
installed or the firmware was
not recently downgraded,
remove the embedded
device, wait 10 seconds,
and then reinsert the device,
ensuring that it is fully seated
in the chassis.
Should the issue persist,
contact HP support.
Check the connections
on both ends of the Fibre
Channel cables and make
sure that the switch, hub, or
other system that the fibre is
connected to is operating
properly and is properly
configured.
Should the issue persist,
contact HP support.