Func.
Code
C073
Communication data length selection
• 07 7-bit data
C074
Communication parity selection
• 00 No parity
• 02 Odd parity
C075
Communication stop bit selection
• 01 1 stop bit
C078
Communication wait time
C081
[O] input span calibration
C082
[OI] input span calibration
C083
[O2] input span calibration
C085
Thermistor input tuning
C086
[AM] terminal offset tuning
C087
[AMI] terminal meter tuning
C088
[AMI] terminal offset tuning
C121
[O] input zero calibration
C122
[OI] input zero calibration
C123
[O2] input zero calibration
C091
Debug mode enable
• 00 Display
C101
Up/Down memory mode selection
• 00 Clear last frequency (return to F001)
• 01 Keep last freq. adjusted by UP/DWN
C102
Reset mode selection
• 00 Cancel trip state at input signal ON transi-
tion, Stops inverter if in Run Mode
• 01 Cancel trip state at signal OFF transition,
Stops inverter if in Run Mode
• 02 Cancel trip state at input signal ON transi-
tion, no effect if in Run Mode
C103
Restart mode after reset
• 00 Restart at 0 Hz
• 01 Resume after frequency matching
C111
Overload setting (2)
Name / Description
• 08 8-bit data
• 01 Even parity
• 02 2 stop bits
• 01 No display
30
Default
Set
Value
Value
–FE/FU/FR
7
00
1
0.
Factory
calibrated
105.0
0.0
80.
Factory
calibrated
00
00
00
00
Rated
current of
each inverter