Download Print this page

GE CV936 Owner's Manual & Installation Instructions page 10

Vented range hoods

Advertisement

Available languages

Available languages

Installation instructions
DUCT FiTTiNGS
Use this chart
to compute
maximum
permissible
lengths
for duct runs to
Outdoors.
Note: Donot exceedmaximumpermissibleequivalent
lengths!
Maximum
duct length:
100 foot for vent hoods•
Flexible
ducting:
If flexible
metal
ducting
is used,
all the equivalent
feet values
in
the ruble should
be doubled.
The flexible
metal
duct should
be straight
and
smooth
and
extended
as much
as possible.
Do NOT
use flexible
plastic
ducting.
Note: Any homeventilation system,suchasa
ventilation hood,may interruptthe properflow of
combustionair and exhaustrequiredbyfireplaces,
gas furnaces,gas water heatersand othernaturally
vented systems.To minimizethe chanceof interruption
of suchnaturallyventedsystems,follow the heating
equipmentmanufacturer'sguidelinesandsafety
standardssuchasthose publishedby NFPA andASHRAE.
Duct
Piece
Dimensions
7" Round,
straight
• -1/4 x 12"
straight
7" 90 ° elb(m
7" 45 ° elbox_
• -1/4 x 12"
90 ° elbo_
• -1/4 x 12"
45 ° elb o_,_
:_
p*
• -I/4 x 12"
90 ° fiat elbo_
Total
Equivalent
Quandty
Equivalent
Length*
Used
Length
ltt.
(per
%ot
length)
lit.
(per foot
length)
14it.
9it.
15 ft.
9it.
36fl.
@_11_
7 p' i'Ot/lld
to
p,
• -1/4
x12"
transition
• -1/4
xl2"to
/
rmnd
transition
lit.
lit.
This Hood Must Use 7" Round
Duct. It Can Transition To
3=1/4 ,, × 12" Duct
Kit - JXDWI
Order
ldtJXDW1
if your installation
requires
horizontal
ducfing
f)om
the
top of the hood
through
the back
wall and:
* You have an 8 fk. ceiling
and
need
to
use aJXCH
Series
Chimney
Corm;
or
* You have a 12"cabinet
or 12" soflit
that
the hood
is to be mounted
beneath.
This
ldt provides
a duct transition
f}'oIIl
7** rotlnd
to
31/4 " X 10"
rectangular
for through-the-wall
venting.
Using a smaller diameter duct size
will reduce performance
7 p* I'Ot/lld
to
•-1/4
x 12"
transition
90 ° elb(m
• -1/4 x12
t_ / rmnd
transition
90 ° elb(m
7" Round
wall cap
with damper
• -1/4 x 12"
_all cap _ith
damper
4it.
4it.
28 it. (21 it. x_ithout
damper)
26 it. (19 it. x_ithout
damper)
7" Round
roof cap
39 fk
Round
roof vent
24 ft.
*Actual length of straight duct plus duct fitting equivalent.
Equivalentlength of duct pieces are basedon actual
tests conducted by GE Evaluation Engineering and
reflect requirementsfor good venting performance
with any ventilation hood.
Total Duct Run