GE CV936 Owner's Manual & Installation Instructions page 13

Vented range hoods

Advertisement

Available languages

Available languages

Installation instructions
DETERMINE
HOOD, DUCTWORK
AND WIRING LOCATIONS
• Keep the wood support
piece
and
its screws for
later
h_stallation.
Do not discard.
• Measure
desired
distance
flom
the bottom
of the
hood
to the cooking
surf_ce,
24" rain.
to 36 "Max.
Refer
to the previous
page
if the access<n T duct cover
will be used.
• Use a level to draw a horizontal
line indicating
the
bottom
of the hood.
• Use a level to draw the cooktop
centerline
location.
• Measure
15-3/8
"up flom
the horizontal
line fin the
bottom
of the hood.
Draw another
horizontal
line.
• Measure
18" up flom
the line for the botton_
of the
hood,
draw another
horizontal
line to indicate
the
top of the hood.
FOR VERTICAL (Straight Up) DUCTING:
* If venting out the ceiling, extend the centerline
fbrward on the ceiling.
- Measure 6-7/8" flom drywall to mark centerline
fin a
7-1/2" dia. duct hole on the ceiling.
- If drywall is not present,
add drywall thickness
to the
6-7/8" dimension.
Venting
through
a soffit
or upper
cabinet.
* Follow
the same
procedure
ff_r ceiling
ducting
to cut
the 7-1/2"
dia. hole through
the top of the cabinet
or
soffit.
* See Step 4, page
15 fin derails
to cut opening
fin duct
transition.
,,
, _FOR CEILING
6-7/,8 ....
',,/VENT DUCTING
benterllne/o
vvall_X_-
_
F== E,ectrica,
/
7-1/2" Dia.Hole
X
\
,
i
"\\
=
,
"\\
i
"\,4,
_Centerline
8" Min. Above
FOR
,
Topof Hood
Topof Hood
Wood
18" ,
Support
II
15-3/8"
|
i
Electrical
Bottomof Hood ,r
II
,
i
,
,
i
FOR DUCTING THROUGH
REAR WALL:
* Measure the supplied
duct transition
with any straight
run length
of duct used, plus 90 o elbow height. Draw a
horizontal
line on the wall intersecting
the centerline.
House Wiring
Location:
* Thej
unction
box is fastened
to the back of the hood
on the right
side. See illustrations
fin hood
knockout
locations.
Note:
The j unction
box can be relocated
to the inside
top of the hood.
House
wiring
may enter
thejtmcdon
box fYom the rear
or the top of the hood
at the right
side.
To route
house
wiring
through
the ceiling
or soffit:
- Cut a hole approximately
1" dia., 5-7/8"
finward
on
the ceiling,
11-1/8"
to the right
of the centerline
fin.
30" models.
To route
house
wiring
through
the wall:
- Cut a hole approximately
1" dia., 10-1 / 16" down
fYom the top of the hood,
11-1/S"
to the right
of the
centerline
fin 30" models.
* Remove
top or rear knockout
depending
on your
installation.
* Install
strain
relief
onto
back or top of hood.
Knockout
Locations
, j ............
11-1/8"for30" Models
11-1/8"for 30" models
13