Configuration Tool
Table 7-3
Possible operations and displays in the Parameter tab
Field / button
Print table in text file
Download parameters
(online connection
required)
Update parameters
(online connection
required)
Upload parameters
(online connection
required)
Observe actual values
(online connection
required)
7-5
Outputs parameter assignment in a text file.
The currently displayed parameter assignment is output in a text file. The
data can be further processed, e.g., with Excel.
Notice
Parameter assignments cannot be restored from these text files. In order to
restore a parameter assignment, it must have previously been saved in U600
format.
See open/save in General functions (Chapter 7.2).
Loads the parameters of the connected device
The parameters of the connected device, including its description data (e.g.
texts in all languages), are loaded. This can take several minutes. The
parameter assignment is also implicitly reloaded from the device.
Notice
The displayed parameter assignment data are overwritten. The archived data
are not accepted from the device, i.e. the displayed archived data are
retained.
See also Connect / disconnect online connection (Chapter 7.2.1).
Loads the parameters of the connected device without parameter description
The parameters of a connected device are loaded without the description
data. This can take several minutes.
Notice
The displayed parameter assignment data are overwritten. The archived data
are not accepted from the device, i.e. the displayed archived data are
retained.
See also Connect / disconnect online connection (Chapter 7.2.1).
Transfers the writable values of the loaded parameters to the connected
device
The following values/parameters are not transferred into the device:
Values of write-protected parameters
Operationally critical parameters
Display parameters
Command parameters
To transfer the parameter, an online connection must be established to the
device and the Confiiguration Tool correspondingly authorized. See also
Connect / disconnect online connection (Chapter 7.2.1) and
Authorization (Chapter 7.2.2).
Current values / states of actual values observed
After observation has been activated, the current values and/or states are
readout from the device cyclically, and the displays in the Parameter tree and
the Parameter table are updated.
See also Connect / disconnect online connection (Chapter 7.2.1).
Meaning / instruction
Siemens AG 2010 All Rights Reserved
®
SICLOCK
TC100 Operating Instructions