3.1.3 Communication parameters

F10M communication parameters
Parameter name
Inverter number
f802
Data type
f830
selection
Input reference
f831
setting 1
Input reference
f832
setting 2
Input reference
f833
setting 3
Input reference
f834
setting 4
Input reference
f835
setting 5
Input reference
f836
setting 6
Monitor output
f841
setting 1
Monitor output
f842
setting 2
Monitor output
f843
setting 3
Monitor output
f844
setting 4
Monitor output
f845
setting 5
Monitor output
f846
setting 6
Title
Setting value
0 to 255
0, 1
0 to 16
0 to 16
Sets inverter station address. (Note 1)
When using a message transmission, set the address of the
master station to 0 and address of the inverter station to 1 or
over.
Selects type of transmitting and receiving data.
0: VFA7 mode
1:μ s 250 mode
Sets scan transmission data to be received.
0: Without setting
1: Command
2: Speed reference value
3: Auxiliary speed reference value
4: Torque limit value
5: Positive torque limit value
6: Negative torque limit value
7: Torque command value
8: Synchronized torque bias
9: Tension torque bias
10: Load sharing gain
11: Drooping gain
12: Speed loop proportional gain
13: Speed loop accumulative gain
14: Terminal output data
15: Inertia moment ratio
16: Expansion command
Sets scan transmission data to be sent.
0: Without setting
1: Status
2: Operation frequency
3: Speed feedback value (real time)
4: Speed feedback value (1-second filter)
5: Internal torque reference value
6: Output amperage
7: Exciting amperage
8: Torque amperage
9: Overload accumulative value
10: Deleted torque of acceleration/deceleration torque
11: Motor counter data
12: Error code
13: Input terminal data
14: VI input
15: RR input
16: RX input
12
E6580772
Details