Procedure 2

Message Check

When the power is turned on, the system performs the Initial Reliability Test (IRT) installed
in the BIOS ROM. When the test detects an error, an error message is displayed on the screen.
Make sure no floppy disk is in the FDD. Turn on the computer and check the message on the
screen. When an OS starts from the 2.5" HDD, go to Procedure 3. Otherwise, start with
Check 1 below and perform the other checks as instructed.
Check 1
If either of the following messages appears, go to Check 3. If the following
messages do not appear, perform Check 3.
Insert system disk in drive
Press any key when ready .....
Non-System disk or disk error
Replace and press any key when ready
Check 2
Using the SYS command of the Free-DOS, transfer the system to the 2.5" HDD.
If the system is not transferred, go to Procedure 3. Refer to the Free -DOS Manual
for detailed operation.
If the following message appears on the display, the system program has been
transferred to the HDD.
System Transferred
If an error message appears on the display, perform Check 3.
Check 3
2.5" HDD(s) and the connector(s) of system board may be defective (Refer to the
steps described in Chapter 4, Replacement Procedures for disassembling.). Insert
HDD(s) to the connector(s) firmly. If it is (or they are) firmly connected, go to
Procedure 3.
Qosmio X500 Maintenance Manual (960-Q08)
or
2 Troubleshooting Procedures