184
PERC 3 BI OS C o nfigurati on Ut ili ty
Press <Esc> to exit the Advanced Menu.
10
You are prompted to accept the settings.
Highlight Accept and press <Enter>.
11
Do not initialize the logical drive.
Press <Esc>. and choose Yes at the Save prompt.
12
Exit the BIOS Configuration Utility.
13
Reboot the system.
14
Set the host system to boot from SCSI, if such a setting is available.
15
Exiting the PERC 3 BIOS
Configuration Utility
Perform the following steps to exit the BIOS Configuration Utility.
Press <Esc> when the Management Menu displays.
1
Choose Yes at the prompt.
2
Reboot the computer.
3
The PERC 3 BIOS message appears again.
Press <Esc> when the BIOS Configuration Utility prompt appears.
4

Setting Hardware Termination

If you are using the PERC 3/DC for clustering, you must use hardware
termination. Otherwise, software termination may be used. The headers
used for SCSI termination are:
J2 Termination Enable is a three-pin header that specifies control of
the SCSI termination for channel 0.
J3 Termination Enable is a three-pin header that specifies control of
the SCSI termination for channel 1.
J5 Termination Enable is a three-pin header that specifies control of
the SCSI termination for channel 2.
J7 Termination Enable is a three-pin header that specifies control of
the SCSI termination for channel 3.