208
Troub les hoot in g

Other BIOS Error Messages

Table 13-3 explains the other BIOS error messages that can display.
Ta b l e 1 3 - 3 . O t h e r B I O S E r r o r M e s s a g e s
Message
Problem
The physical disk roaming
Following
feature did not find the
SCSI disk not
physical disk with the
found and no
displayed SCSI ID. No
empty slot
slot is available to map the
available for
physical drive. PERC 3
mapping it
cannot resolve the
physical drives into the
current configuration.
The physical drive
Following
roaming feature found the
SCSI IDs have
same data on two or more
the same data
physical drives on channel
y, z
x with SCSI IDs a, b, and
Channel x: a,
c. PERC 3 cannot
b, c
determine the drive that
has the duplicate
information.
The PERC 3 is unable to
Unresolved
determine the proper
configuration
configuration after
mismatch
reading both NVRAM and
between disks
Configuration on Disk.
and NVRAM on
the adapter
Suggested Solution
Reconfigure the array.
Remove the drive or drives
that should not be used.
Press <Ctrl><M> to run
the BIOS Configuration
Utility. Choose
—>
Configure
New
Configuration to create a
new configuration.
CAUTION: This will delete
any existing configuration.