NEC Express5800 320La System Configuration Manual page 52

Linux network operating system configuration guide
Hide thumbs Also See for Express5800 320La:
Table of Contents

Advertisement

Fatal High Limit > Fatal High Reset > Warning High Limit > Warning High
Reset
The high temperature limit can range from 30 C to 70 C (86 F to 160 F).
Warning high/report - (warning high limit) When the temperature exceeds this
value, a warning alert message is generated and the status of the Agent changes
to warning. The warning high limit must meet the following condition:
Fatal High Limit > Fatal High Reset > Warning High Limit > Warning High
Reset
Warning low/report - (warning low limit) When the temperature falls below
this value, a warning alert message is generated and the status of the Agent
changes to warning. The warning low limit must meet the following condition:
Warning Low Reset > Warning Low Limit > Fatal Low Reset > Fatal Low
Limit
Fatal low/report - (fatal low limit) When the temperature falls below this value,
a fatal alert message is generated and the status of the Agent changes to
abnormal. The fatal low limit must meet the following conditions:
Warning Low Reset > Warning Low Limit > Fatal Low Reset > Fatal Low
Limit
The low temperature limit can range from -10 C to 30 C (15 F to 86 F).