iNSTALLATiON DRAWINGS (LDE Series only)
NOTE
SAVE FOR THE USE OF THE LOCAL
ELECTRICAL INSPECTOR.
CLEARANCES AND DIMENSIONS
(Figure 1)
To install range refer to the following
Figure 1.
For installation in CANADA,
a Free-standing
range
is not to be installed closer than 15/32(12ram) from
any adjacent
surface.
• You should use two or more people to move
and install range. (Excessive
Weight Hazard)
- Failure to do so can result in back or other injury.
• You never pull or push any handles of upper
& lower door to move and install range.
- Failure to do so can result in serious damage
to
the door of the range.
• You should make sure that the wall
covering, countertop and cabinets
around the range can withstand the heat
(up to 194°F) generated by the range.
- Discoloration,
delamination
or melting may occur•
- This range has been designed to comply with
the maximum allowable wood cabinet
temperatures
of 194°E
_
3" (7.6cm) _1
_"_---_ 24"
....... __: . .........____._ _
(60.9cm)_-----_'_
/_
..................
_
_
3" (7,6cm)
I
...... --]7"
I AcceptaMe _"
,_'2m'_°u
_l_rth
I
I
I elet_tertiCa_La"_
_1
I __
jl
3"
Counter
/
,
_
/I
_]_
H.4cm)top
height
7"a b_n e_'_'_
/
/
_1
1(60.crr
I
_
_I
36"
__--_
_
,iL_'_(28cm)._l
(91.4 :m)l
_-'_l
...,:
:1
/
............_
i
I
I
II /
/
I'a01netl _
_4_i
.,-z_
J
• Cabinet storage space located above
the surface
units should
be avoided.
• You should install a range hood that
projects horizontally a minimum of 5
inches beyond the bottom of the cabinets.
if cabinet Storage is to be provided.
- The risk of burns or fire by reaching over the
,_ heated surface elements can be reduced:
j
crr
Minimum
I
1
\
!
t
*'15"
(38.1cm)
A = 30"(76.2 cm) For U.S.A
= 30"(76.2 cm) ~ 31"(78.7 cm) For CANADA
FIGURE 1
FIGURE 2
MINIMUM
DIMENSIONS
(Figure 2)
* 30"(76.2 cm) minimum
clearance between the top of the cooking surface and the bottom
of an
unprotected
wood or metal cabinet; or 24"(60.9 cm) minimum
when bottom
of wood or metal cabinet is
protected
by not less than V4"(6.4 cm) flame retardant
millboard
covered with not less than no. 28 MSG
sheet steel, 0.015"(0.381
mm) stainless steel, 0.024"(0.610
mm) aluminum
or 0.020"(0.508
mm) copper.
** 15"(38.1 cm) minimum
between countertop
and adjacent cabinet bottom.