• Only a 4=conductor power-supply cord kit
rated 120/240 volts, 50 amperes and
marked for use with ranges with closed=
loop connectors or open=end spade lugs
with upturned ends shall be used. The
middle (neutral) wire of the power cord or
4=wire conduit has to be connected to the
middle post of the main terminal block.
The other two wires of the power cord or
conduit have to be connected to the
outside posts of the main terminal
connection block. The 4th ground wire
must be connected to the frame of the
range with the ground screw.
- Failure to do so can result in electrical shock, severe
persona ! injury or death:
_,
Follow the instructions
under "[-4] CONNECT RANGE
CORD" on page 5 to correctly install the strain relief.
1. Remove the lower 3 screws from the terminal
block
and retain them. (Refer to Figure 9.)
Remove the ground
screw and retain it.
2. Remove ground strap and discard as shown
in Figure 9.
Do not discard any screws.
3. Insert the ground screw into the power cord ground
wire terminal
ring and secure it to the range frame.
4. Insert the 3 screws through
each power cord
terminal
ring and into the lower terminals
of the
terminal
block. Make sure that the center wire
(white/neutral)
is connected
to the center lower
position
of the terminal
block.
Tighten 3 screws securely
into the terminal
block.
5. Go to page 10.
4-wire connection
Black
White
Red
_f_
Terminal
block
roon
FIGURE 9
Install the conduit as follows:
Remove the Conduit connection
plate from the rear of
lower oven and rotate it as shown in Figure 5. The
conduit
hole (11/8 ") must be used.
First, prepare the conduit wires as shown in Figure 10.
3 wire
1"
3/8"
(2.5cm)
(0.9 cm)
Conduit
t'_
_,r,__
3_/_
connection
q8.9 cm)
plate
or
FIGURE 10
4 wire
31/2"
1"
_
3/8"
...... Ground
\
(1._/_'m)
w,re
(6.9cm)
Second, install conduit
as shown in Figure 6.
For conduit installations,
after purchasing
a strain
relief, insert it in the conduit
hole (11/8"). Then install
the conduit through
the body of strain relief and
fasten the strain relief with its ring. Reinstall the
bracket.
For conduit connections
:
If the wire in the conduit
is copper it must be 8 or 10
AWG wi ri ng.
If the wire in the conduit
is aluminum
it must be 6 or 8
AWG wi ri ng.
1. Loosen the lower 3 screws from the terminal block.
(Refer to Figure 11.)
2. Insert the bare wire (white/neutral)
end through the
center terminal block opening.
Do not remove ground strap connections.
3. Insert the two side bare wire ends into the lower left
and the lower right terminal
block opening,
Tighten the 3 screws securely into the terminal block.
(approximately
35 - 50 IN-LB)
4, Go to page 10.
3-wire connection
Black
White
Red
Terminal
Conduit _
connection plate
]_
FIGURE 11