Command Specifications
(1) Read/Write error recovery parameters (page code = 1)
Table 4.15 lists the format of the page descriptor of this MODE SELECT
parameter.
Table 4.15 MODE SELECT parameters: read/write error recovery parameters
Bit
7
Byte
0
0
1
2
AWRE
Default
1
Variable
1
3
Default
Variable
4
Default
Variable
5
6
7
8
Default
Variable
9
10-11
Default
Variable
4-26
6
5
4
0
0
0
X'0A' (Page Length)
ARRE
TB
RC
1
0
0
1
1
1
Number of retries during READ
X'3F'
X'FF'
Correctable Bit Length
X'FF'
X'00'
X'00' (Head Offset Count)
X'00' (Data Strobe Offset Count)
X'00' (Reserved)
Number of retries during WRITE
X'3F'
X'FF'
X'00' (Reserved)
Recovery Time Limit
X'7530'
X'FFFF'
3
2
1
0
0
0
ERR
PER
DTE
1
0
0
1
1
1
0
1
DCR
0
1
(=63
times)
(=63
times)
(=30s)
C141-C009