Maintenance Monitor List - Electrolux EN18WI30LS Service Manual

Gas water heater
Hide thumbs Also See for EN18WI30LS:
Table of Contents

Advertisement

<EN18WI30LS, EP18WI30LS, EN19WI30LS, EP19WI30LS>

Maintenance Monitor List

Data
No.
Gas quality judging result
02
Total Plug-in Time
03
04
Total Combustion Time
05
Total Combustion Time
Number of Ignition Times
07
Number of Ignition Times
08
Fan Rotational Frequency
10
Service Reminder Hours Accumulated
11
Service Reminder Hours Accumulated
12
14
Total Flow Rate
18
19
Condensate trap clogging
Calculated Fan Speed
20
Water Inlet Thermistor
30
Detection Temperature
Water Outlet Thermistor
31
Detection Temperature
Heat Exchanger Thermistor
32
Detection Temperature
Exhaust Thermistor
36
Detection Temperature
Air Inlet Thermistor
38
Detection Temperature
39
Fan Motor Current Value
Simple Self-diagnosis Counter
47
48
Initial Fan Speed Correction
Final Fan Speed Correction
49
50
51
52
Position of Main Water
60
Position of Bypass Water
62
87
Circuit Board ID1: Product 1
88
Circuit Board ID2: Product 2
89
Circuit Board ID3: Version
Error Code History 1
91
Error Code History 2
92
Error Code History 3
93
Error Code History 4
94
Error Code History 5
95
Error Code History 6
96
Error Code History 7
97
Error Code History 8
98
*1 To view the maintenace monitors of another unit in a multi-system installation, press the FLOW
METER ALARM SET button (while in monitor mode) to switch to the desired unit.
*2 A difference in the calculated (#20) and the measured (#10) fan speeds of
*3 When remote controller is in °F/Gallons mode.
*4 When remote controller is in °C/Liters mode.
(Display Reading
Item
Multiplier
Judging [000] ,NG_Lo [1100] ,NG_Hi [1300] ,NG_Lo_fix (Dip fixation) [1109] ,NG_Hi_fix (Dip fixation) [1309]
X
1
X 1
X
1
X
X
1
X
X 1
X
1
X
X
O
u
p t
u
( t
%
)
X 1
X
X 1
X
X 1
X
X 1
X
X 1
X 1
X 1
X 1
X
[0:xx]
X 1
X 1
X
FF No.
FF+FB No.
X
Output
X
X 2
Control Valve
X 2
Control Valve
[1:xy]
[2:xy]
[3:xy]
Most Recent Error Code
Next Most Recent Error Code
Next Most Recent Error Code
Next Most Recent Error Code
Next Most Recent Error Code
Next Most Recent Error Code
Next Most Recent Error Code
Next Most Recent Error Code
Data
Minimum
X
Multiplier)
Value for
Unit
Indication
0
0
hour
100 hours
hour
1 hours
0
0
0
hour
1000 hours
1
0
time
10 times
0
0
0
0
time
10000 times
rpm
25 rpm
1
0
1 hours
time
1000 hours
0
0
0
time
gal/min
0.1 gal/min
0
1 .
0
1 .
L/min
0.1 L/min
%
%
rpm
25 rpm
1
0
F
1 F
0
1 .
C
0.5
C
F
F
1
0
1 .
C
0.5
C
F
1
F
0
1 .
C
C
0.5
F
1
F
C
1
C
F
1
F
C
1
C
1
0
10 mA
mA
Decimal
1
%
%
%
1 %
0.1
1 . 0
0
1 .
0.1
0
1 .
0.1
Step
Step
31
Remarks
Disp. Range [000] - [1310]
Disp. Range [000] - [999]
Disp. Range [000] - [1999]
Disp. Range [000] - [999]
Disp. Range [000] - [1999]
Disp. Range [000] - [999]
Disp. Range [000] - [65]
1
OFF [000] , ON [001]
Disp. Range [014] - [050]
Disp. Range [-10] - [010]
Disp. Range [000] - [1999]
[000] - [036]
[100] - [110]
[100] - [110]
[000](open) - [1350](closed)
[000](open) - [1350](closed)
A=101,B=102,C=103,
A=201,B=202,C=203,
A=301,B=302,C=303,
If the same error code is repeated,
it will appear in the history list
twice. If it is repeated more than
twice, it will only appear twice.
500 or less is normal.
*3
*4
*2
*3
*4
*3
*4
*3
*4
*3
*4
,Z=126
,Z=226
,Z=326

Hide quick links: