Manifold Gas Pressure Adjustment - Electrolux EN18WI30LS Service Manual

Gas water heater
Hide thumbs Also See for EN18WI30LS:
Table of Contents

Advertisement

Manifold Gas Pressure Adjustment

Note 1)
Use the following procedure to adjust the manifold gas pressure only
if it can be done with a high flow rate through the unit.
Note 2)
When the manifold gas pressure is adjusted, the front cover will be off.
Adjust the manifold gas pressure to the value of "Cover Off" in the table
(because it is not possible to adjust the manifold gas pressure with the
front cover on).
(1)
With a manometer or pressure gauge connected to the manifold
pressure tap, press and hold the "Maximum Manifold Pressure
Set Button". Use the "Manifold Gas Pressure Increase and
Decrease Buttons" to adjust to the correct pressure.
(2)
Press and hold the "Minimum Manifold Pressure Set Button".
Use the "Manifold Gas Pressure Increase and Decrease Buttons"
to adjust to the correct pressure.
(3)
Repeat steps (1) and (2) until both are at the correct pressure.
Manifold Gas Pressures Maximum and Minimum Values
Model Name
Gas type
EN18WI30LS
NG
EP18WI30LS
LPG
* Manifold gas pressure values are subject to change without prior notice.
Please check the latest burner specification table.
Manifold Gas Pressures Maximum and Minimum Values
Model Name
Gas type
EN19WI30LS
NG
EP19WI30LS
LP
*Manifold gas pressure values are subject to change without prior notice.
Please check the latest burner specification table.
Supply Pressure
Manifold Pressure (inch H
(inch H
O)
Max value
2
7.9
2.95
11.0
3.60
Manifold Pressure (inch H
Supply Pressure
(inch H
O)
Max. value
2
3.20
7.9
11.0
3.70
Manifold Gas Pressure
Increase Button
Manifold Gas Pressure
Decrease Button
Minimum Manifold
Pressure Set Button
Maximum Manifold
Pressure Set Button
O) Cover off
2
Min value
1.10
1.35
O) Cover off
2
Min. value
1.50
1.50
36
UP
DOWN
MIN
MAX

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ep18wi30lsEn19wi30lsEp19wi30ls

Table of Contents