Floppy Disk And Storage Envelope - Siemens SATURN IIE EPABX Installation Test Procedures

Epabx
Table of Contents

Advertisement

SATURN IIE EPABX
Installation Test Procedures
5 . 0 1
General. The SATURN IIE EPABX is a Stored-Program-
Controlled (SPC) system. The system is shipped with two iden-
tical floppy disks that contain the basic operating and the
installation-dependent data. The operating program uses the
installation-dependent data, commonly referred to as the sys-
tem data base, to complete and process calls as required by
the customer. This information includes such items as the
number of station lines and trunks in the system, as well as
their operating characteristics.
The exact equipment configuration of the SATURN IIE Sys-
tem must be defined in the data base in order for the system
to operate properly. Depending on how the system is ordered,
the data base is supplied in a standard format or, on request,
c a n b e s u p p l i e d c o m p l e t e l y d e f i n e d a n d p r e p a r e d b y S i e m e n s .
When the standard data base format is supplied, via the
SATURN EPABX Data Base Preparation practice, the equip-
ment configuration of the particular installation-site must be
evaluated to determine if additional information must be ad-
ded to the floppy disks. The floppy disks are updated via a
service terminal. The procedures for defining the data base
and inputting the data to memory are described in the
SATURN
EPABX
Data
Base
SATURN EPABX Customer Memory Update (CMU) Proce-
dures practice.
5 . 0 2
ing the Power-Up/Output Voltage Tests in Section 4.00, the
C e n t e r i n g 1
H o l e
Read/W
Window
Protective
Envelope
Storage
Envelope
Preparation
practice
and
I
I
Figure 5.00 Floppy Disk and Storage Envelope
system's operating program, contained on the floppy Uisks,
is loaded into the FDD modules for the initial processor in-
itialization. Both floppy disks are loaded, with either disk
placed in either drive (FDDO or FDDI). Before proceeding with
the loading procedures indicated in Table 5.00, the following
precautions must be observed when handling the floppy disks.
Figure 5.00 illustrates the floppy disk and storage envelope.
a .
Prior to using a floppy disk, leave disk in the same en-
vironment as the FDD module for at least 5 minutes.
b. Do not place heavy objects on floppy disk.
c. Do not write on floppy disk.
d. Do not touch floppy disk suriace while hand!ing.
Damage to FDD head may occur due to skin oil pick-
ing up dirt.
e .
Always return floppy dislc to storage envelope when it
is not in use.
5 . 0 3
Inputting CMU Data to F!oppy Disk. After satisfac-
torily loading the operating disks as indicated in Table 5.00,
refer to the SATURN EPABX Data Base Preparation practice
which defines the particular system's data base, and SATURN
EPABX Customer Memory Update (CMU) Prccsdures
tice to input the installation-dependent da?a to memory
Index
Hole
Issue 1, May 1986
prac-