Hitachi WJ200 Series Quick Reference Manual page 76

Wj200 series inverter single-phase input 200v class three-phase input 200v class three-phase input 400v class
Hide thumbs Also See for WJ200 Series:
Table of Contents

Advertisement

CALL NOW 800-985-6929
Option
Code
52
53
56
57
58
59
60
61
62
65
66
67
68
69
70
73
Option
Code
77
78
81
82
83
84
85
86
255
CALL NOW 800-985-6929
http://www.automatedpt.com
Input Function Summary Table
Terminal
Function Name
Symbol
ATR
Enable torque
command input
KHC
Clear watt-hour data
MI1
General purpose input
(1)
MI2
General purpose input
(2)
MI3
General purpose input
(3)
MI4
General purpose input
(4)
MI5
General purpose input
(5)
MI6
General purpose input
(6)
MI7
General purpose input
(7)
AHD
Analog command hold
CP1
Multistage-position
switch (1)
CP2
Multistage-position
switch (2)
CP3
Multistage-position
switch (3)
ORL
Limit signal of homing
ORG
Trigger signal of
homing
SPD
Speed/position
changeover
Input Function Summary Table
Terminal
Function Name
Symbol
GS1 *
GS1 input
GS2 *
GS2 input
485
Start EzCOM
PRG
Executing EzSQ
program
HLD
Retain output
frequency
ROK
Permission of Run
command
EB
Rotation direction
detection (C007 only)
DISP
Display limitation
no
No function
http://www.automatedpt.com
Description
ON
Torque control command input is enabled
OFF
Torque control command input is disabled
ON
Clear watt-hour data
OFF
No action
ON
General purpose input (1) is made ON under EzSQ
OFF
General purpose input (1) is made OFF under EzSQ
ON
General purpose input (2) is made ON under EzSQ
OFF
General purpose input (2) is made OFF under EzSQ
ON
General purpose input (3) is made ON under EzSQ
OFF
General purpose input (3) is made OFF under EzSQ
ON
General purpose input (4) is made ON under EzSQ
OFF
General purpose input (4) is made OFF under EzSQ
ON
General purpose input (5) is made ON under EzSQ
OFF
General purpose input (5) is made OFF under EzSQ
ON
General purpose input (6) is made ON under EzSQ
OFF
General purpose input (6) is made OFF under EzSQ
ON
General purpose input (7) is made ON under EzSQ
OFF
General purpose input (7) is made OFF under EzSQ
ON
Analog command is held
OFF
Analog command is not held
ON
Multistage position commands are set according to
the combination of these switches.
OFF
ON
OFF
ON
OFF
ON
Limit signal of homing is ON
OFF
Limit signal of homing is OFF
ON
Starts homing operation
OFF
No action
ON
Speed control mode
OFF
Position control mode
Description
ON
EN60204-1 related signals:
OFF
Signal input of "Safe torque off" function.
ON
OFF
ON
Starts EzCOM
OFF
No execution
ON
Executing EzSQ program
OFF
No execution
ON
Retain the current output frequency
OFF
No retention
ON
Run command permitted
OFF
Run command is not permitted
ON
Forward rotation
OFF
Reverse rotation
ON
Only a parameter configured in b038 is shown
OFF
All the monitors can be shown
ON
(input ignored)
OFF
(input ignored)
74
Email: charles@automatedpt.com
Email: charles@automatedpt.com

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents