External Tone Ringer/Night Chime Output; Smdr Output; Pc Connection; Relay Contact - NEC UNIVERGE SV8100 Configuration Manual

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

Issue 2.00
5.5
5 - 18
5.4.7

External Tone Ringer/Night Chime Output

Output Level: –10 dBm
Output Impedance: 600 Ω
Relay Contact Rating: 500 mA, 24 Vdc
5.4.8

SMDR Output

Female Connector (LAN) Standard DB-9 (straight)
5.4.9

PC Connection

Female Connector (LAN) Standard DB-9 (straight)
5.4.10

Relay Contact

All Relay Contact Ratings: 500 mA, 24Vdc

Battery Backup

The UNIVERGE SV8100 system has battery backup functions for system
backup and for memory backup.
5.5.1

System Backup (Optional)

During a power failure, the system can be backed up using the
CHS2U BATT MTG KIT for a backup time of 10 minutes or one of the
CHS LARGE BATT SETs for a backup time ranging from 45~180
minutes. The CHS2U GW can be backed up using the CHSGW
SMALL BATT BOX for a backup time of 10 minutes.
5.5.2

Memory Backup

The CD-CP00 blade battery retains the Clock/Calender and Last
Number redial (LNR) buffers for each station when the CD-CP00
blade encounters a power loss. With a fully charged battery, the
settings are retained for about three years. The System Programmed
memory (Customer Database) is stored in nonvolatile Memory and
can be erased only by a First Initialization. After power is restored,
the system blade returns to normal operation.