Siemens SINAMICS S120 Manual page 284

Chassis power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Motor-side power components
6.3 dv/dt filter plus Voltage Peak Limiter
Table 6- 29
Technical data of the dV/dt filter plus voltage peak limiter, 3 AC 500 ... 690 V, Part 4
Order number
Suitable for Motor Module
Type rating of the Motor
Module
I
thmax
Degree of protection
dV/dt reactor
Power loss
- At 50 Hz
- At 60 Hz
- At 150 Hz
Connections
- To the Motor Module
- Load
- PE
Max. permissible cable
length between dV/dt
reactor and motor
Dimensions
Width
Height
Depth
Weight, approx.
Voltage peak limiter
Power loss
- At 50 Hz
- At 60 Hz
- At 150 Hz
Connections
- To the dV/dt reactor
- DC
- PE
Dimensions
Width
Height
Depth
Weight, approx.
Two dV/dt reactors are required for these dV/dt filters. The technical data provided applies to one dV/dt reactor.
1)
Note
Cable lengths for versions with two dV/dt reactors
For versions with 2 dV/dt reactors, the cable lengths specified in the table do not change.
282
6SL3000-
2DH38-1AA0
6SL3320-
1TG38-1AAx
kW
800
A
810
IP00
kW
0.828
kW
0.867
kW
0.927
2 x M12
2 x M12
M6
m
mm
445
mm
385
mm
312
kg
160
kW
0.106
kW
0.1
kW
0.091
M10
M10
M8
mm
309
mm
1312.5
mm
400
kg
72
2DH41-3AA0
1)
1)
1TG38-8AAx
900
1270
IP00
0.865
0.904
0.966
2 x M12
2 x M12
M6
300 (shielded)
450 (unshielded)
445
385
312
164
0.15
0.14
0.128
M10
M10
M8
309
1312.5
400
72
Manual, (GH3), 01/2013, 6SL3097-4AE00-0BP3
2DH41-3AA0
2DH41-3AA0
1)
1TG41-0AAx
1TG41-3AAx
1000
1270
IP00
0.865
0.904
0.966
2 x M12
2 x M12
2 x M12
2 x M12
M6
445
385
312
164
0.15
0.14
0.128
M10
M10
M8
309
1312.5
1312.5
400
72
Chassis power units
1)
1200
1270
IP00
0.865
0.904
0.966
M6
445
385
312
164
0.15
0.14
0.128
M10
M10
M8
309
400
72

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents