4. SPECIFICATIONS OF ELECTRICAL PARTS

4-1. Indoor Unit
RAV-SM564UTP
*
, RAV-SM804UTP
No.
Parts name
1
Fan motor (for indoor)
2
Thermo. sensor (TA-sensor)
3
Heat exchanger sensor (TCJ-sensor)
4
Heat exchanger sensor (TC-sensor)
5
Float switch
6
Drain pump motor
RAV-SM1104UTP
*
, RAV-SM1404UTP
No.
Parts name
1
Fan motor
2
Thermo. sensor (TA-sensor)
3
Heat exchanger sensor (TCJ-sensor)
4
Heat exchanger sensor (TC-sensor)
5
Float switch
6
Drain pump motor
*
SWF-230-60-2R
Ø6 mm, 1000 mm
Ø6 mm, 1000 mm
FS-0218-102
MDP-1401
*
, RAV-SM1604UTP
*
ICF-280-150-1
Ø6 mm, 1000 mm
Ø6 mm, 1000 mm
FS-0218-102
MDP-1401
– 22 –
Type
Output (Rated) 60 W
310 mm
10 kΩ at 25°C
10 kΩ at 25°C
10 kΩ at 25°C
Type
Output (Rated) 90 W
310 mm
10 kΩ at 25°C
10 kΩ at 25°C
10 kΩ at 25°C