Mitsubishi Electric FR-A8NC Instruction Manual page 93

Plug-in option cc-link communication function
Hide thumbs Also See for FR-A8NC:
Table of Contents

Advertisement

LED status
Inverters (FR-A8NC)
Master
unit
Station 1
RUN
L.RUN 
SD
RD
L.ERR 
RUN
TIME 
L.RUN 
LINE 
SD
or
RD
TIME 
L.ERR 
LINE 
RUN
L.RUN 
SD
RD
L.ERR
: On, : Off, : Flicker, : Any of on, flicker or off
92
HOW TO CHECK FOR ERROR USING THE LEDS
Station 2
Station 3
RUN
RUN
Since the L.RUN LEDs of the FR-A8NC on
L.RUN 
L.RUN 
station 2 and later are off, the CC-Link
SD
SD
dedicated cable between the remote I/O units
A and B is open or disconnected from the CC-
RD
RD
Link communication connector.
L.ERR 
L.ERR 
RUN
RUN
L.RUN 
L.RUN 
SD
SD
The CC-Link dedicated cable is shorted.
RD
RD
L.ERR 
L.ERR 
RUN
RUN
L.RUN 
L.RUN 
The CC-Link dedicated cable is wired
SD
SD
improperly.
RD
RD
L.ERR
L.ERR
Cause
Referring to the LED "on"
condition, search for an open
point and repair.
Identify the shorted wire out of
the three wires (blue, white,
yellow) of the CC-Link dedicated
cable, and repair the wire.
Check if the three wires (blue,
white, yellow) of the CC-Link
dedicated cable are correctly
inserted to the one-touch
communication connector plug. If
any improper connection is
found, correct the connection.
Corrective action