Maximum Usp Vm Components To Be Installed In The Primary Rack; Maximum Usp Vm Components To Be Installed In The Secondary Rack - Hitachi Universal Storage Platform VM Installation Planning Manual

Hide thumbs Also See for Universal Storage Platform VM:
Table of Contents

Advertisement

Maximum USP VM Components to be Installed in the Primary Rack

Control Frame = 10U.
Additional SVP/Battery Backup Chassis = 2U.
This chassis obtains its power from the control frame and must be
installed directly above the control frame.
When installing a USP VM that does not include this chassis, leave a 2U
space vacant above the control frame to allow for the installation of the
chassis in the future.
This chassis is required when one or both of the following conditions are
met:
-
System is equipped with 80 GB or more of cache memory. In this
instance, an additional battery will be installed within the chassis.
-
The secondary (back-up) service processor (SVP) will be installed.
The secondary SVP will be installed in this chassis.
First Disk Chassis = 12U.
Second Disk Chassis = 12U.

Maximum USP VM Components to be Installed in the Secondary Rack

3rd Disk Chassis = 12U.
4th Disk Chassis = 12U.
2–14
Hitachi Universal Storage Platform VM Installation Planning Guide
Figure 2-7: Rail Kit Alignment and Spacing