Electrolux 6000 Service Manual page 54

5.75 cu. ft. dryer gas & electric
Hide thumbs Also See for 6000:
Table of Contents

Advertisement

Failure code
E4A
The drying time has exceeded program
time for cycle.
E 5B
No heat.
E 68
One of the keys (buttons) is
stuck closed (active).
E 8C
High limit thermostat has trip to many times
in a certain amount of time.
E AF
Microcontroller has been reset
by Watchdog timer
Failure code chart
Fault condition
.
Press Pause Cancel and SELECT buttons for
6 seconds to exit test modes. Position cycle
selector to NORMAL, temperature selector to
HIGH HEAT and touch START. Check for any
thing that would extend dry times such as: no
heat, restricted vent, blower fan blade broken
or loose, dryer installed in closet with solid door,
or bad connection in moisture sensor bar cir
cuit or dirty bars. If dryer operates normally but
code returns, replace electronic control.
Refer to flow chart dryer does not heat.
Enter function test mode and perform key
(button) test to determine which button is at
fault. Carefully free the and perform the test
again. If button is free but the key struck code
still exists, replace electronic control.
Check for blocked lint filter, blocked exhaust,
air leaks around air duct, broken blower fan
blades, worn or loose drum seals, dryer installed
in closet with solid doors or door seal not
correctly seated.
Clear code, exit mode and start dryer. If
problem persists, replace electronic control.
54