Scan Params; Keystroke Output - Motorola ET1 Integrator Manual

Enterprise tablet
Hide thumbs Also See for ET1:
Table of Contents

Advertisement

Picklist - This parameter allows the imager to decode only the bar code that is directly under the
cross-hair/reticle (+) part of the pattern. This feature is most useful in applications where multiple bar
codes may appear in the field of view during a decode session and only one of them is targeted for
decode.
Disable – Disables Picklist mode, so any bar code within the field of view can be decoded (default).
Centered - Enables the Picklist mode so that only the bar code in the center of the image is decoded.
This is most useful when used in conjunction with the static and dynamic reticle viewfinder modes.
Note: This mode is only valid for decoder modules that supports a viewfinder. If one tries to set this for
a unsupported decoder then the device would issue an error.
Illumination mode - Turns illumination on and off.
On - Illumination is on.
Off - Illumination is off (default).
Viewfinder Mode - This setting displays the Viewfinder modes supported for scanning.
Viewfinder - Only Viewfinder is enabled.
Static Reticle - Displays the Viewfinder as well as draws a red reticle in the center of the screen
which helps tracking the bar code (default).

Scan Params

Allows the configuration of Code Id and decode feedback options.
Code ID Type - A Code ID character identifies the code type of a scanned bar code. This is useful when
the reader is decoding more than one code type. Select a code ID character to insert between the prefix
and the decoded symbol.
Code ID Type None - No prefix (default).
Code ID Type Aim - A standards based three character prefix.
Code ID Type Symbol - A Symbol defined single character prefix.
Decode Audio Feedback - Select an audio tone to sound upon a good decode.

Keystroke Output

Use to configure the Keystroke Output Plug-in for the profile.
Enabled - Enables or disables this plug-in. A check in the checkbox indicates that the plug-in is
enabled (default - enabled).
Basic data formatting - Allows the configuration of any data formatting for the related Output Plug-in.
When the plug-in is disabled, any data is passed on without modification.
Enabled - Enables or disables Basic Data Formatting. A check in the checkbox indicates that it is
enabled (default - enabled).
Prefix to data - Add characters to the beginning of the data when sent.
Suffix to data - Add characters to the end of the data when sent.
Send data - Set to transfer the captured data to the foreground application. Disabling this option
prevents the actual data from being transmitted. However, the prefix and suffix strings, if present,
are still transmitted even when this option is disabled (default - enabled).
Send as hex - Set to send the data in hexadecimal format. A check in the checkbox indicates that
the plug-in is enabled (default - disabled).
DataWedge Configuration 4 - 15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents