CHAPTER 3 REMCS Service Start Procedure

3.2 REMCS Center Registration

You can specify the FQDN only when using an Internet connection through the user port.
If you specify an FQDN, confirm that a DNS server is specified in [Network] - [Network Interface] of the
MMB Web-UI.
-
Sender e-mail address (with permission to send external e-mails)
-
Whether to enable the mail server for partitioned e-mail sending
-
Confirm whether your mail server is enabled for partitioned e-mail sending.
To connect to the REMCS Center through the REMCS port, you first need to set the Maintenance Port in
[Network] - [Network Interface] of the MMB Web-GUI. Before making the port settings, prepare such
information as the IP address to be assigned, subnet mask, gateway address, and destination SMTP
server address.
You can also set the IP address of the REMCS port by using the following CLI.
Set command: Sets the REMCS port.
set maintenance_ip <ip address> <netmask> <gateway address>
<SMTPaddress>
Note
You do not need to specify <gateway address> and <SMTP address> if you make point-to-point (P-P)
REMCS connections. In this case, specify 0.0.0.0 for both <gateway address> and <SMTP address>.
Display command: Displays the REMCS port settings.
show maintenance_ip
For details on the commands, see Chapter 2 MMB CLI (Command Line Interface) Operations in the
PRIMEQUEST 2000 Series Tool Reference (CA92344-0539).
Note
Do not perform registration during the maintenance work.
3.2
REMCS Center Registration
This section describes how to register with the REMCS Center.
Use the following registration procedure.
-

3.2.1 Starting REMCS

-
3.2.2 Setting the connection configuration
-
3.2.3 Setting up the environment
-
3.2.4 Setting the periodic connection schedule
-
3.2.5 Setting the customer information
-
3.2.6 Confirming the registration result
-
3.2.7 Checking the connection
3.2.1 Starting REMCS
To start REMCS, select the [Maintenance] - [REMCS] - [REMCS] menu in the MMB Web-UI.
If no registration has been made so far, the window shown in
Instructions] window
If the registration has already been made, the window shown in
Registration Instructions] window
window
appears.
For details on the procedure, see
appears.
does not appear. Instead, the window shown in
CHAPTER 4 REMCS Service Operations
FIGURE 3.2 [Customer Information Registration
FIGURE 3.2 [Customer Information
8
FIGURE 4.1 [REMCS initial]
CA92344-0542-02