Individual Control Center Items
These programming items are set independently for each control center connected to the control panel.
Programming
Item Number
Item
Control Center
Control Center 1: 811
Brightness
Control Center 2: 821
Control Center 3: 831
Control Center 4: 841
Control Center
Control Center 1: 814
Backlight
Control Center 2: 824
Extinguish Mode
Control Center 3: 834
Control Center 4: 844
Default
= Country-specific default. Select this programming item to hear the updated default value.
4.3.8

User Programming Items

Item
Programming Item
Number
861
Passcode Length
7001
Installer Passcode
(User 0)
7011
Master User
Passcode (User 1)
862
Duress User
(User 22) Enabled
863
RFID Token
Password
Default
= Country-specific default. Select this programming item to hear the updated default value.
4.3.9

Factory Default

Programming Item
Item Number
9999
Factory Default
4.4

Exit Programming

Press [#] repeatedly until the system says "goodbye." This ends the phone session.
Bosch Security Systems, Inc. | 5/07 | F01U025147-01
Easy Series (ICP-EZM2) | Installer Guide | 4.0 Programming
Description
5 = Brightest display (1 to 5)
0 = Display is always on
1 = Display is dim until presence is
detected or button is pressed
2 = Display is off until presence is
detected or button is pressed
3 = Display is off until a valid token is
presented or passcode is entered
Description (Range)
Set the length of all passcodes
(4 or 6 digits).
Four-digit Range: 1111 to 5555
Six-digit Range: 111111 to 555555
Four-digit Range: 1111 to 5555
Six-digit Range: 111111 to 555555
0 = Duress user disabled
1 = Duress user enabled
Duress User passcode:
Six digits: 111111
Four digits: 1111
Use this item to prevent unauthorized copying of tokens
(00000000 to FFFFFFFF).
Do not change this item once tokens
are added to the system.
Description
Enter 9999 to restore all factory default values. All programming items, except
for the country code, are reset when you restore the factory default values.
This item also deletes all wireless data, but does not default the wireless hub.
Entry
Control Center 1:
5
Control Center 2:
5
Control Center 3:
5
Control Center 4:
5
Control Center 1:
0
Control Center 2:
0
Control Center 3:
0
Control Center 4:
0
Entry
4
5432
543211
1234
123455
0
12345678
53

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents