RLDA " in the LCD).
Specified range (read power): 600
8. Perfome the light power adjustment. Set the light power at
4.55mW by using VOL+ and VOL- key of the remote controller. If
at this time the amperage between TP405 and TP406 (laser
current) is 70mA or higher, it is conceivable that theoptical pickup
is defective.
Specified range (light power): 4.5mW
Caution:
Do not allow the write power to even momentarily reach or exceed
5 mW. Doing so will result in damage to the optical pickup.
9. Press the
LP " on the LDC. At this time, the data is written to EEPROM.).
10. Press the PLAY key on the remote controller (" LP " changes to "
T1 EX " on the LCD.).
11. Remove the laser power meter. Laser power adjustment is
finished.
[REFERENCE]
For use of MD cartridge type laser power meter: / We recommend you to use a stick type laser
power meter for laser power adjustment of this set. / But if available is a MD cartridge type
only, arrange the set as shown in
mode", start the laser power adjustment. / (As for the method of disassembly, refer to "5.
Operation checks and main component replacementprocedures".)
6.2.3. Magneto-optical disc automatically adjustment
1. Have " T2 EX " indicated on display, and move the optical pickup
to around the center (only when a MD cartridge type laser power
meter is used).
key of the remote controller (" RLDA " changes to "
Fig. 9
, and from the state of "6.2.1. Enter the adjustment
W±10% or lower
Fig. 8