GE Euro Simon Installation Instructions Manual page 15

Table of Contents

Advertisement

Note
If the customer ever adds a
phone or other phone device
to another phone jack, full
line seizure no longer exists.
Inform the customer to con-
tact you if they want to add a
phone or other device so
that you can rewire for full
line seizure by adding an
RJ-31X.
Euro Simon Security System
E
- - - -
- - - - -
BRN
GRY
B
GRN
RED
A
TIP
RING
(+)
(-)
D
Red
Green
Black
White (or Yellow)
C
Red
Green
Premises
Phone Jack
Wires
Figure 8. Full Line Seizure Wiring with RJ-31X
¾
Full Line Seizure Wiring without RJ-31X
1. Connect the green, red, brown, and gray wires of the 8-conductor phone cord included with
the panel as shown in Figure 9. Use weatherproof wire connectors for all splices.
2. Connect the plug end of the phone cord to the panel LINE IN jack
¾
Full Line Seizure Wiring with 1 Premises Phone
If a single phone is all that exists on the premises, full line seizure can be accomplished without
an RJ-31X.
1. Disconnect the phone from the premises phone jack and plug it into the panel PHONE jack
(A in Figure 10). This jack is disconnected automatically whenever the panel reports.
Connect the phone cord included with the panel to the panel LINE IN jack and the premises
phone jack (B in Figure 10)
A C
A C
H W I N 2
D C O U T
H W I N 1
Brown
(T1)
Green
(Tip)
Figure 9. Full Line Seizure Wiring without RJ-31X
Gray
(R1)
Red
- - - -
A C
A C
H W I N 2
D C O U T
H W I N 1
(Ring)
- - - - -
10