Option 46: Fire Shutdown - 2-Way; Option 47: 2-Way Mode; Option 48: Panic Talk - 2-Way; Option 49: Arming Leds Shutdown - GE Euro Simon Installation Instructions Manual

Table of Contents

Advertisement

Note
Option 33: Audio Verification
must be on for this feature to
work.
Note
Option 33: Audio Verification
must be on for this feature to
work.
Euro Simon Security System
¾
To turn on Sensor Alarm Restoral Report, press:
Add—Option #—45—1, 2, or 3—DONE.
¾
To turn off Sensor Alarm Restoral Report, press:
Delete—Option #—45—DONE.
Option 46: Fire Shutdown - 2-Way (Default = off)
Determines whether system sirens are silenced during a 2-way audio session (on) or not (off).
Beeps sound every 10 seconds while sirens are silenced.
¾
To turn on Fire Shutdown - 2-Way, press:
Add—Option #—46—DONE.
¾
To turn off Fire Shutdown - 2-Way, press:
Delete—Option #—46—DONE.

Option 47: 2-Way Mode

Determines whether the panel hangs up and waits for a callback from the central station operator
before starting a 2-way audio session (on), or stays on the line with the central station for an
instant audio session.
¾
To turn on 2-Way Mode (callback), press:
Add—Option #—47—DONE.
¾
To turn off 2-Way Mode (instant), press:
Delete—Option #—47—DONE.
Option 48: Panic Talk - 2-Way (Default = off)
Determines whether the central station operator can talk to the user during a silent alarm (on) or
just listen in on the premises (off).
Silent alarms occur when sensors learned into groups 02 or 03 are tripped, when the Panic Code
is entered, or when the panel Police button is pressed and Option 74: Silent Panel Police Panic is
turned on.
¾
To turn on Panic Talk - 2-Way, press:
Add—Option #—48—DONE.
¾
To turn off Panic Talk - 2-Way, press:
Delete—Option #—48—DONE.
Option 49: Arming LEDs Shutdown (Default = off)
Determines whether the panel LEDs (buttons) turn off 30 seconds after the last button press (on),
or remain on for the entire arming period (off).
¾
To turn on Arming LEDs Shutdown, press:
Add—Option #—49—DONE.
¾
To turn off Arming LEDs Shutdown, press:
Delete—Option #—49—DONE.
Option 50: RF Jam Detect (Default = off)
Determines whether the panel checks for and reports RF interference/jam to the central station
(on), or not (off).
If this option is on and the panel receives a constant 433 MHz signal, the panel speaker
announces "Option 50 detected" and reports the condition to the central station. If this option is
off, the panel does not detect an RF jam.
¾
To turn on Jam Detect, press:
Add—Option #—50—DONE.
¾
To turn off Jam Detect, press:
28

Advertisement

Table of Contents
loading

Table of Contents