3.3.3

Fixing the Magnets

Being careful not to move the Magnets from their measured position, fix the Magnets in place.
Remove the masking tape on one side of the Magnet only. Remove the backing tape on the back of the Magnet, and affix
it permanently to the position in which it had been temporarily affixed.
3.3.4

Magnet Calibration

After 3.3.3Fixing the Magnets, then Magnet Calibration is performed. Press [Calibration Start].
Rotate the crank slowly at around 30rpm, and check that the count in the [Magnet Calibration] screen rises on each side
for each rotation. When the count reaches 5/5 or higher, the [Save] button becomes active. Press the [Save] button to
store the Calibration results. A message will be shown indicating Calibration success, then press [OK.] to conclude.